Technical Parameters
 

Model / Specification

S-100-3

S-100-5

S-100-7-5

S-100-12

S-100-15

S-100-24

S-100-27

S-100-48

DC output voltage

3V

5V

7.5V

12V

15V

24V

27V

48V

Output voltage error (Note2)

±2%

±2%

±1%

±1%

±1%

±1%

±1%

±1%

Rated output current

20A

20A

13.6A

8.5A

6.7A

4.5A

3.7A

2A

Output current rage

0-20A

0-20A

0-13.6A

0-8.5A

0-6.7A

0-4.5A

0-3.7A

0-2A

Wave and noise(Note3)

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

±0.3%

±0.3%

±0.2%

±0.2%

±0.2%

Load stability(Note5)

±0.5%

±0.5%

±0.5%

±0.3%

±0.3%

±0.2%

±0.2%

±0.2%

DC output power

60W

100W

102W

102W

100.5W

108W

99.9W

96W

Efficiency

70%

78%

80%

81%

81%

84%

84%

84%

Adjustable range for DC voltage

2.85-3.3V

4.75-5.5V

6.75-8.25V

10.8-13.2V

13.5-16.5V

21.6-26.4V

26-32V

43.2-52.8V

AC input voltage range

85~132VAC/180~264VACselected by switch47~63Hz;255-370VDC

Input current

2.4A/115V 1.2A/230V

AC impulse current

Cold-start current 30A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload protection

 

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.03%°C(0~50°C)

Setup rise hold up time

200ms,100ms,30ms

Vibration

10~500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval:1.5KVAC,Input and enclosure:1.5KVAC,Output and enclosure:0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure:0500VAC/100M Ohms

Working temperature and humidity

-10°C~+60°C,20%~90%RH

Store temperature and humidity

-20°C~+85°C,10%~95RH

Overall dimension

199*98*38mm

Weight

0.5Kgs

Safety standards

Meet UL1012

EMC standards

……

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25°C 70%Rh,Humidity
2.Error,include the setting error, line stability and load stability.(Note:5)
3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting
4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.
5.Load stability test: The load is from 0% to 100%,others 60%.