CONTEC CMS8000 CE hospital ICU cheap patient monitor (1600067311631)

Share on:


Price:RUB 28,257.90
Price in USD:Details

Quantity:


Product Overview

Description

Contec CMS8000 patient monitor multi-parameter

 

CMS8000

1.jpg

 

 

 

Introduction
The monitor has abundant functions that can be used for clinical monitoring with adult, pediatric and neonate. Users may select different parameter configuration according to different requirements. The monitor, power supplied by 100-240V~,50/60Hz,  adopts 12.1'' color TFT LCD displaying real-time date and waveform. It can synchronously display eight-channel waveform and full monitoring parameters equipped with an optional 48mm thermal recorder. The monitor can be connected to the central monitoring system via wire or wireless network to form a network monitoring system.
This device can monitor such parameters as ECG, RESP, NIBP, SpO2, and dual-channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Its replaceable internal battery brings lot of convenient for patient moving.

Functions
Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP
1)ECG   Heart rate(HR)
      ECG waveform
      Arrhythmia and ST-segment analysis
2)RESP   Respiration rate(RR)
      Respiration waveform
3)SpO2   Oxygen saturation(SpO2)
      Plethysmogram(PLETH) waveform
      Pulse rate(PR)
      Bar graph
4)NIBP   Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN)
5)TEMP   T1, T2, TD
6)IBP(optional)  CH1:SYS,DIA,MAP
CH2:SYS,DIA,MAP
IBP waveform
7)CO2(optional)  EtCO2
InsCO2:Inspired Minimum CO2
AwRR:Air Way Respiration
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc.

Features
1)12.1'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakh, Polish, Czech).
2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection.
3)All-round monitor for adult, pediatric and neonate.
4)With standard interface, oxygen graph, trend graph, big character interface and view bed, convenient to observe.
5)Finish all operations by keys and knobs.
6)Maximum 8-channel waveform synchronous display.
7)Display 7-lead ECG waveform on one screen, cascade ECG waveform display
8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling.
9)Heart rate variability (HRV) analysis function
10)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data.
11)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
12)Drug concentration calculation and titration table functions.
13)One-touch printing of trend graph
14)Connect to Central Monitoring System by 3G, Wi-Fi or wired mode.
15)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.
16)Anti-high frequency surgical unit, defibrillation-proof (special leads are necessary).

Performance
1.ECG
Lead mode: 3-lead or 5-lead
Lead selection: I, II, III, aVR, aVL, aVF, V
Waveform: 5-lead, dual-channel
3-lead, single-channel
Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV
Scan speed: 12.5mm/s, 25 mm/s, 50 mm/s
HR:
Measurement and alarm range: 15~350 bpm
Accuracy: ±1 % or ±1 bpm, whichever is greater
Alarm accuracy: ± 2 bpm
Resolution: 1 bpm
ST-segment monitoring:
Measurement and alarm range: -2.0 mV ~ +2.0 mV
Accuracy: -0.8 mV~+0.8 mV  ±0.04 mV or ±10%, whichever is greater
Other range: unspecified
Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,
PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
Pacemaker: yes
2.RESP
Method: R-F(RA-LL) Impedance
Respiration rate:
Measurement and alarm range: 0~150 rpm
Resolution: 1 rpm
Measurement accuracy: ±2 rpm
Alarm accuracy: ±3 rpm
Apnea alarm: 10~40s
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s
3.NIBP
Method: Oscillometry
Mode: Manual/AUTO/STAT
Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes
Measurement period in STAT mode: 5 minutes
Measurement and alarm range: 10 ~ 270 mmHg
Resolution: 1 mmHg
Cuff pressure accuracy: ±3 mmHg
Measurement accuracy:
Maximal mean deviation: ±5 mmHg
Maximal standard deviation: 8 mmHg
Over-pressure protection:
Adult mode: 297±3 mmHg
 Pediatric mode: 240±3 mmHg
 Neonatal mode: 147±3 mmHg
4.SpO2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Measurement accuracy: 70%~100%: ±2%;
0%~69%: unspecified
5.PR
Measurement and alarm range: 30 ~ 250 bpm
Measurement accuracy: ±2 bpm or ±2%, whichever is greater
6.TEMP
Channel: dual-channel
Measurement and alarm range: 0 ~ 50℃
Resolution: 0.1 ℃
Accuracy: ±0.1 ℃
7.EtCO2
Method: Sidestream or Mainstream
Measuring Range: 0~150mmHg
Resolution:
0~69 mmHg, 0.1 mmHg
70~150 mmHg, 0.25 mmHg
Accuracy:
0~40 mm Hg ±2 mm Hg
41~70 mm Hg ±5%
71~100 mm Hg ±8%
101~150 mm Hg ±10%
AwRR Range: 2~150 rpm
AwRR Accuracy: ±1BPM
Apnea Alarm: Yes
8.IBP
Channel: dual-channel
Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and Alarm Range: -10~300 mmHg
Resolution 1 mmHg
Accuracy: ±2% or 1mmHg, whichever is greater
9.Power supply: 100-240V~, 50/60Hz
10.Safety classification: Class I, type CF defibrillation-proof applied part

Physical characteristic
Dimension: 314 mm(L) × 145 mm(W) × 264 mm(H)
Weight: 3.9 Kg
1.jpg3.jpgCMS8000-2.jpgCMS8000-3.jpgCMS8000-4 (2).jpgCMS8000-6 (2).jpgCMS8000-11.jpgCMS8000-34.jpgs-l1600 (2).jpgs-l1600 (6).jpg

 