Dog RLN pregnancy veterinary test kit

Share on:


Price:RUB 68.24 - RUB 90.99
Price in USD:Details

Quantity:


Product Overview

Description

Early Pregnancy Rapid Test (After 25 days of having sex)
1. INTENDED USE
S&CEarly Pregnancy Rapid Test is a sandwich lateral flow immunochromatographic assay for the qualitative detection of early pregnancy factor in dog’s serum

Assay Time: 5-10 min

Sample: serum

2. PRINCIPLE OF THE ASSAY
S&C Early Pregnancy Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window.The testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample hole on the device, the liquid will laterally flow on the surface of the test strip. If there is enough Early Pregnancy Rapid Test in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of Early Pregnancy Rapid Test in the sample..
3. KIT COMPONENT
- 10×foil pouches, each containing one cassette, one pipette and a desiccant

- 10×centrifugal tubes

- Product Manual
4. TEST PROCEDURE
1st Step
- Collect dog’s blood 1ml Centrifugal: 1500speed/minute. (If samples don’t need to be test immediately, then shall be kept in cold storage; if samples are kept over 24 hours, then shall be cryopreservation).
2nd step
- Take out the cassette from the foil pouch and place it horizontally.
3rd Step
- Open the transparent cap of the Sample tube, then Break off the top section, put the top of the sample tube down.
4th Step
-Gradually drip 2-3 drops of serum into the sample hole “S”.
5th Step
- Interpret the result in 5-10 minutes. Result after 10 minutes is considered as invalid..
6. STORAGE
The kit can be stored at room temperature (2-30°C). The test kit is stable through the expiration date (18 months) marked on the foil pouch. DO NOT FREEZE. Do not store the test kit in direct sunlight.
7. PRECAUTIONS
- For best results, please strictly adhere to these instructions.
- All reagents must be placed at room temperature before running the assay.
- Do not remove test cassette from its pouch until immediately before use.
- Do not reuse the test kit.
- Do not use the test beyond its expiration date marked on the foil pouch.
- The components in this kit have been quality control tested as standard batch unit. Do not mix components from different lot numbers.
Packing&Delivery
0.0293 s.