DN150mm 4-Channel M-bus Bulk Ultrasonic Water Meter

Share on:


Price:
Price in USD:Details

Quantity:


Product Overview

Description


 


Ultrasonic Water Meter


 


 


                                   SCL-61D5, SCL-61D6 series


                                     Stainless steel pipe section


                          R400, R500, R800 for option


                                                       Supports NB-IoT, RS-485, M-bus communications


 


SCL-61D6 1.jpg


 


 


 


Features:
1. Online self-verification function for the accuracy of deployed products.
2. Integrated mechanical design with protection class of IP68, able to work in long-term water immersion.
3. Low initial flowrate and high accuracy class.
4. Multiple transmission methods, RS-485, M-Bus, NB-IoT and RF radio frequency.
5. High-quality seamless pipe made from stainless steel, precision machining by robot workstation.
6. Recyclable stainless-steel pipe for the reduction of use costs.
7. Energy saving and environmental protection, no casting, no pollution, material saving.


 


Advantages:
1. Large dynamic range R800, reached the precise measurement of minimum flowrate.
2. 4-channel design for all series, dual-fracture surface measuring method, improve the accuracy under complex flow regime.
3. Integrated flowrate and pressure measurement, able to reach the demand of monitoring.
4. Micro power consumption technology, battery-powered with lifetime over 10 years.
5. Intelligent manufacturing for flexible customization.


6. It is suitable for accurate measurement and trade settlement of the master-meter flowrate of urban water supply pipeline and household metering, and also suitable for DMA district metering management, which solves the problems of high initial flowrate and non-measurement of small flowrate in traditional meters.


 


 


System & Platform:


Huizhong Company has various remote water systems, such as Water Supply Measurement System, DMA District System, etc.


 


 


222.JPG 3333.JPG


 


  


 


Quick overview of Huizhong company:


 


Huizhong Instrumentation Co., Ltd -  one of leading manufacturers of Ultrasonic water meter, Flow meter and Heat meter from 1998. For more information, please visit our official website: http://en.huizhong.co/home


 


 


Huizhong factory-2.jpg


    2.jpg


 


5.jpg


 Huizhong factory-3.jpg


 


Test Bench of DN15-DN40.jpg


 


 


 


Technical Parameters


SCL-61D5


 





























































































ItemParameter
SCL-61D5(Reducing Diameter)
MediumWater or other homogeneous fluids in full pipe flow
Accuracy ClassClass 1Class 2
Dynamic RangeR250R315R500R250R315R400R500R630R800
Nominal Diameter

DN65~DN300


DN65~DN300DN50~DN300
Max. Permissible Working Pressure1.0MPa/1.6MPa/2.5MPa, standard is 1.6MPa (only DN200 is 1.0MPa)
Pressure LossΔp 10
Ambient Environment-25℃~55℃,≤100%RH
Temperature ClassT30, T50, T70, default: T30
Class of Upstream Flow Field SensitivityU0
Class of Downstream Flow Field SensitivityD0
Category of Climate & Mechanical Environment ConditionsClass O
Class of Electromagnetic CompatibilityE2
Data CommunicationOptical Interface/RS-485/M-Bus/RF/NB-IoT/Analogy Switch Output
Data StorageUsing EEPROM for storage of cumulative flowrate and cumulative running time; Data can be stored for 100 years after power failure; The data of the past 24 months can be automatically stored
Power Supply

Lithium battery powered, one battery can continuously work for over 10 years


DC10V~DC36V, ≥20mA (Please specify on ordering)
Protection ClassIP68
For the non-integral meter version, the cable connecting the measuring unit and display is in a standard length of 1.5m. For cable length other than this, please specify on ordering.

       


Technical Parameters


SCL-61D6
























































































ItemParameter
SCL-61D6 (Diameter Pipe)
MediumWater or other homogeneous fluids in full pipe flow
Accuracy ClassClass 1Class 2
Dynamic RangeR250R315R250R315R400
Nominal Diameter

DN65~DN300


DN50~DN300
Max. Permissible Working Pressure1.0MPa/1.6MPa/2.5MPa, standard is 1.6MPa (only DN200 is 1.0MPa)
Pressure LossΔp 10
Ambient Environment-25℃~55℃,≤100%RH
Temperature ClassT30, T50, T70, default: T30
Class of Upstream Flow Field SensitivityU0
Class of Downstream Flow Field SensitivityD0
Category of Climate & Mechanical Environment ConditionsClass O
Class of Electromagnetic CompatibilityE2
Data CommunicationOptical Interface/RS-485/M-Bus/RF/NB-IoT/Analogy Switch Output
Data StorageUsing EEPROM for storage of cumulative flowrate and cumulative running time; Data can be stored for 100 years after power failure; The data of the past 24 months can be automatically stored
Power Supply

Lithium battery powered, one battery can continuously work for over 10 years


DC10V~DC36V, ≥20mA (Please specify on ordering)
Protection ClassIP68
For the non-integral meter version, the cable connecting the measuring unit and display is in a standard length of 1.5m. For cable length other than this, please specify on ordering.

 


  


 


Packaging & Shipping:


1 water meter in one wooden box


 


packing.jpg 


 


 


0.0182 s.