1. Input voltage (on demand)Single-phase AC220V/AC110V + / - 15%; 50 hz \\ 60 hz
Three-phase AC380V/AC220V + / - 15%; 50 hz \\ 60 hz
2. The output voltage can be adjustable range (0 ~ 2000V).
3. The output constant current value can be adjusted range (0 ~ 2000A).
4. Adjustment rate of source voltage: stable pressure is less than 0.5%; Load adjustment rate: stable pressure is less than 1%; Constant flow is less than 2%.
5. Ripple voltage: total ripple voltage Vpp is less than 2%; Machine efficiency: > 86%.
Parameter
Brand | VOITA--VT-ADP5200 |
AC Wide Input | 1 Phase AC220V±15%, 50/60hz |
Output Range | Constant Voltage 0~5V(Variable Or Appointed) Constant Current 0~200A (Variable Or Appointed) |
Power | Max 1000W |
Source Voltage Regulation | Constant Voltage ≤0.2% |
Load Regulation | Constant Voltage ≤1%; Constant Current≤2% |
Line Regulation: | Constant Voltage ≤0.3% |
Ripple Voltage | Total Ripple Vpp≤2% (Max Voltage) 100Hz Ripple: Vpp≤0.5%(Max Voltage) |
Operation Environment Temperature | (-10~45)℃ |
Efficiency | ≥89% |
Digital Meter | Voltage Meter And Current Meter |
Digital Display | Precision Of Output Voltage±1.5% |
Insulating Resistance | Input-Output:≥20MΩ |
Input— Shell:≥20MΩ | |
Output-Shell:≥80MΩ | |
Insulating Strength | Input-Output:AC1500V,10ma,1minute |
Input— Shell:AC1500V,10ma,1minute | |
Output-Shell:AC1500V,10ma,1minute | |
Unbalancedness Of Equalized Current | ≤5%+2.5A |
Protection | Temperature Control Fan, Over-Temperature Automatic Protection; Output Overvoltage, Over-Current And Short-Circuit Protection; Switch-On Delay Soft Starting Can Avoid The Over Swung Output Voltage When Switching On. |
Over-Temperature Protection | (70~80)℃ |
MTTF | ≥50000h |
External Dimension | 165×330×88mm |
Weight | NW:3.5(KG) |
Radiating Wind Hole | Internal Radiating Wind Hole |
Customize range | 0-2000vdc 0-2000A can customize base on request |
The adjustable power supply is widely used in industrial control, electronic power, electroplating, communication, scientific research, instrumentation, military, medical, ship, railway and R&D, charge different kind of battery | ||
No. | Application | Detail range |
1 | DC System | Sewage treatment system |
2 | Laboratory | Laboratory research and development |
3 | Charge Battery | All kind of Lead acid battery / lithium battery |
4 | Motor Fields | Electric Vehicle Motor, Electric Vehicle Controller, DC Motor Test |
5 | Electrical Appliances | LED Test & Aging, Energy Saving Bulb Test & Aging, Lamp Test, Tungsten Wire Gasification |
6 | Automotive | Automotive Electronics, High-Power DC Motor, Automotive Motor Controller, Vehicle Lighting, Cigar Lighter |
7 | Electronic Devices | Capacitors, Resistors, Relays, Transistors, Sensors |
8 | Electrochemistry | Electrolysis, Electroplating, Nonferrous Metal Research |
Parameter | Detail Specification for option |
Input | 1 Phase: AC110V±10%,50Hz/60Hz; 1 Phase: AC220V±10%,50Hz/60Hz; 3 Phase: AC380V±10%,50Hz/60Hz; |
Output Voltage | 1~2000V,Stabilizer value. 0% to 100% adjustable |
Output Current | 1~2000A,Constant current value. 0% to 100% adjustable |
Output Power | 150W~100KW |
Addition function | 0-5Vdc /0-10Vdc analog signal control output voltage & current |
0-5Vdc /0-10Vdc analog signal to read-back output voltage & current | |
0-5Vdc /0-10Vdc analog Switch signal to control output ON/OFF | |
4-20mA analog signal control output voltage & current | |
RS232/RS485 Communication port control by computer | |
Noted: Factory accept OEM /ODM Customized service for all customer |