off grid inverter 12v 110v 1500W Home power inverter




Recommend Products




Products Description


About solarway:
Jiaxing Solarway New Energy Company is a Sino-Germany Joint venture which is a professional off-grid power inverter manufacturer in Jiaxing city ,near to Shanghai,China . We are mainly engaged in high-tech DC TO AC inverter, DC TO DC converter, MPPT/PWM
sollar controller, solar panel and other solar system accessories, OEM and ODM service are available.All our products we have CE,RoHs,E-mark certification .We have R & D Center and After-sales Service Center in Beijing, China and Leipzig, Germany to make sure we have new design with patent every year.


Details Images


MODEL
FS1500-112
FS1500-124
FS1500-148
FS1500-212
FS1500-224
FS1500-248
Output
AC Voltage
100/110/120VAC
220/230/240VAC
Rated Power
1500W
Surge Power
Load 120~150%(3min.);3000W(3sec;resistive)
Waveform
Pure Sine Wave(THD<3%)
Frequency
50/60Hz ±0.05%
AC Regulation
±5%
±10%
Power Factor Allowed
COSθ-90°~COSθ+90°
Standard Receptacles
USA/British/Franch/Schuko /UK/Australia/Universal etc. optional
LED Indicator
Green for power on, red for faulty status
USB port
5V 2.1A
5V 2.1A
------
5V 2.1A
5V 2.1A
------
LCD display
voltage, power, protection status ( optional)
Remote control function
default
Remote controller
CR80/CRD80 optional
Input
No Load Current Draw
≤1.1A
≤0.80A
≤0.70A
≤1.1A
≤0.80A
≤0.70A
DC Voltage
12VDC
24VDC
48VDC
12VDC
24VDC
48VDC
Voltage Range
10.5~15VDC
21~30VDC
42~60VDC
10.5~15VDC
21~30VDC
42~60VDC
Efficiency(Typ.)
89%~93%
Fuse
40A×6
20A×6
10A×6
40A×6
20A×6
10A×6
Remote Control
Function (optional)
Protection
BAT. Low Alarm
10.5±0.5VDC
21±1.0VDC
42±2.0VDC
10.5±0.5VDC
21±1.0VDC
42±2.0VDC
BAT. Low Shutdown
10±0.5VDC
20±1.0VDC
40±2.0VDC
10±0.5VDC
20±1.0VDC
40±2.0VDC
Over Load
Shut down output voltage , restart to recover
Over Voltage
15.5±0.5VDC
31±1.0VDC
62±2.0VDC
15.5±0.5VDC
31±1.0VDC
62±2.0VDC
Over Temperature
Shut down output voltage , recover automatically after temperature goes down
Output Short
Shut down output voltage , restart to recover
DC Input Reverse Polarity
By fuse
Earth Fault
Shut off o/p when the load has electrical leakage
Soft Start
Yes, 3-5 Seconds
Environment
Working Temp.
0~+50℃
Working Humidity
20~90%RH non-condensing
Storage Temp.&Humidity
-30~+70℃,10~95%RH
Safety & EMC
Safety Standards
Certified UL 458(only for "GFCI" receptacles)
Certified EN 60950-1; 2006+A11: 2009+A1: 2010+A12: 2011+A2: 2013.
Isolation Resistance
I/P-O/P:100M Ohms/500VDC
EMI Conduction &
Radiation
Certified FCC class A
Certified EN 62040-2:2006,EN61000-3-2; EN61000-3-3;
EMS Immunity
------
Certified IEC61000-4-3, IEC61000-4-6
E-MARK
------
Certified ECE RIO.05:2014
Others
Dimension(L×W×H)
325.2×281.3×112.7mm
Packing
5.2kg;2pcs/11.1kg/0.053m³
Cooling
Load control fan or by thermal control fan
Application
Home and Office appliances,Portable Power Equipment,Vehicle,Yacht and Off-Gid Solar
power systems…etc.




Company Profile




Certifications




Our Advantages




Product packaging




FAQ


1,Q:Why your quotation is higher than other suppliers?
A:In the Chinese market, many factories sell low-cost inverters, which are actually assembled by small unlicensed workshops,largely to cut costs and use substandard components for assembly. There's a major security breach SOLARWAY is a professinonal power inverter R & D, manufacturing and sales enterprises, we deeply cultivated the German market for more than 10 years, each year exports about 50,000-100,000 power inverter to Germany and its surrounding markets Our product quality is worthy of your trust!
..............................................................................................................................................................
2,Q:How many categories does it have according to the output waveform ?
A:Type one: our NM and NS series Modified Sine Wave inverter, which uses PWM pulse width modulation to generate modified sine wave. Due to the usage of intelligent dedicated circuit and high power field effect tube, it greatly reduces the power loss and increases the soft-start function, effectively ensuring the reliability of the inverter. If the power quality is not highly demanded, it is able to meet the needs of most electrical equipment. But it still exists 20% harmonic distortion problems when running sophisticated equipment, can also cause high-frequency interference to radio communications equipment. This kind of
inverter can meet the basic needs of most of our power, high efficiency, small noise, moderate price, and thus become the mainstream products in the market.
Type two: our NP, FS, NK series Pure Sine Wave inverter, which adopts isolated coupling circuit design, high efficiency, high stability of the output waveform, high-frequency technology, small in size, suitable for all kinds of load, can be connected to any common electrical devices and inductive load devices (such as refrigerators, electric drill, etc.) without any interference (eg: buzz and TV noise). The output of pure sine wave inverter is the same as the grid tie power we daily used, or even better, because it does not exist grid tie electromagnetic pollution..
..............................................................................................................................................................
3,Q:What is a resistive load appliances?
A:Generally speaking, appliances like mobile phones, computers, LCD TVs, incandescents, electric fans, video broadcast, small printers, electric mahjong machines, rice cookers etc. All belong to resistive loads. Our modified sine wave inverters can drive them successfully.
..............................................................................................................................................................
4,Q:What is the inductive load appliances?
A:It refers to the application of electromagnetic induction’s principle, produced by high-power electrical products, such as motor type, compressors, relays, fluorescent lamps, electric stove, refrigerator, air conditioner, energy saving lamps, pumps, etc.These products’power are far more than the rated power (about 3-7 times) when start. So only pure sine wave inverter is available to them.
..............................................................................................................................................................
5,How to choose suitable inverter ?
If your load is resistive loads, such as: bulbs, you can choose a modified wave inverter. But if it is inductive loads and capacitive loads, we recommend using pure sine wave inverter. For example: fans, precision instruments, air conditioner, fridge,coffee machine, computer, and so on. Modified wave can be started with some inductive loads, but effect for load using life, because capacitive loads and inductive loads need highquality power.
............................................................................................................................................................
6,How do I choose the size of the inverter ?
Different types of load demand for power are different. You can view the load power values to determine the size of the inverter.
Notice: resistive load: you can choose the same power as the load. Capacitive loads: according to the load, you can choose 2-5 times power. Inductive loads: according to the load, you can choose 4-7 times power.
.............................................................................................................................................................
7,How connection between batteries and an inverter ?
We usually believe that cables connecting battery terminal to inverter shorter is better. If you are just standard cable should be less than 0.5M, but should correspond to the polarity of the batteries and inverter-side outside. If you want to lengthen the distance between battery and inverter, please contact us and we will calculate the recommended cable size and length. Due to long distances using a cable connection, there will be a reduced voltage, which means that the inverter voltage would be far below the
battery terminal voltage, this inverter will appear under voltage alarm conditions.
.............................................................................................................................................................
8,How to calculate the load of working hours requires configuration of the battery size ?
We will usually have a formula to calculate, but it is not hundred percent accurate, because there is also the battery's condition, the old batteries have some loss, so this is only a reference value: Work hours = battery capacity * battery voltage *0.8/load power (H= AH*V*0.8/W)


More Products