Product Information |
Model |
SMT-12030-XC-P |
SMT-24030-XC-P |
|
X=1 for DIM (DW); |
|||
Output |
DC Voltage |
12V |
24V |
|
Voltage Tolerance |
±0.5V |
|
|
Voltage Regulation |
±0.5% |
|
|
Rated current |
CH1=2.5A |
CH1=1.25A |
|
Rated power |
30W (class 2 power units) |
|
|
Load Regulation |
±2% |
|
Input |
Voltage Range |
100-277VAC |
|
|
Frequency Range |
47 - 63Hz |
|
|
Power Factor(Typ.)@ full load |
PF≥0.95/ 230VAC (Full loading) |
|
|
THD(Typ.)@ full load |
≤10%@120VAC ≤20%@230VAC ≤20%@277VAC |
|
|
Efficiency(Typ.)@ full load |
80% @230VAC |
82%@230VAC |
|
AC Current(Max.) |
0.4A |
0.4A |
|
Inrush Current (Typ.) |
7A, 50%, 350us @120VAC; 25A, 50% , 200us @277VAC |
|
|
Leakage current |
<0.5mA |
|
Protection |
Short Circuit |
Hiccup mode, recover automatically after fault condition is removed |
|
|
Over Load |
≤120% ,hiccup model, recover automatically after fault condition is removed |
|
|
Over temperature |
≤100℃±10℃, shutdown output voltage, recover automatically after temperature drop |
|
|
Protection Class |
II |
|
Environment |
Working TEMP. |
-40~+60℃ (see below derating curve) |
|
|
Working Humidity |
20 - 90%RH ,non-condensing |
|
|
Storage TEM.,Humidity |
-40 - +80℃,10 - 95%RH |
|
|
TEMP.coefficient |
±0.03%/℃(0 - 50℃) |
|
|
Vibration |
10~500Hz, 2G 10min./1 cycle,period for 60min. each along X,Y,Z axes |
|
Safety&EMC |
Safety standards |
EN61347-1 EN61347-2-13 (EU) & UL8750 UL1310 (US) |
|
|
Withstand voltage |
I/P-O/P:3.75KVAC (EU) & I/P-O/P:1.5KVAC (US) |
|
|
Isolation resistance |
I/P-O/P:100MΩ/500VDC/25℃/70%RH |
|
|
EMC Emission |
EN55015 EN61000-3-2 EN61000-3-3 (EU) & FCC Part 15 B (US) |
|
|
EMC Immunity |
EN61000-4-2,3,4,5,6,11 EN61547 |
|
Others |
Net Weight |
0.35KG |
|
|
Dimension |
171.5*54*20mm (L*W*H) |
|
|
packing |
/ |
|
Notes |
1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation . 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |
|
Mechanical Specification |
Input terminal with 3P; Live Wire(L) , Neutral Wire (N) . Note: vacant for middle terminal
Output terminals with 6P; LED SEC positive (LED+), LED negative (LED-). Connected to LED light;
Connecting Diagram |