Share on:
Smarts UL listed constant voltage wireless 12v 150W DMX512 led driver
Product Information |
Model |
SMT-12150-XC-A |
SMT-24150-XC-A |
||
X=1 , 2, 3, 4, 5 for DIM (DW); CCT(TW); RGB; RGBW; RGBW+CCT (RGBCW) |
||||
|
DC Voltage |
12V |
24V |
|
Voltage Tolerance |
±0.5V |
|||
Voltage Regulation |
±0.5% |
|||
Rated current |
CH1+CH2+CH3+CH4+CH5=12.5A |
CH1+CH2+CH3+CH4+CH5=6.25A |
||
Rated power |
150W |
|||
Load Regulation |
±2% |
|||
Input |
Voltage Range |
100-277VAC |
||
Frequency Range |
47-63Hz |
|||
Power Factor(Typ.)@ full load |
PF≥0.97@230VAC |
|||
THD(Typ.)@ full load |
≤10% |
|||
Efficiency(Typ.)@ full load |
91%@230VAC 79% |
92.5%@230VAC
|
||
AC Current(Max.) |
1.85A |
1.85A |
||
Inrush Current (Typ.) |
88A (Twidth 120us measured at 50% I peak, COLD START, 230VAC) |
|||
Leakage current |
<0.50mA |
|||
Protection |
Short Circuit |
Hiccup mode ,recovers automatically after fault condition is removed |
||
Over Loading |
≤120% Hiccup mode ,recovers automatically after fault condition is removed |
|||
Over temperature |
100℃±10℃ shut down o/p voltage, automatically recover after cooling. |
|||
Environment |
Working TEMP. |
-40~+60℃ (see below derating curve) |
||
Working Humidity |
20~95%RH, non-condensing |
|||
Storage TEMP. Humidity |
-40~+80℃,10~95%RH |
|||
TEMP .coefficient |
±0.03%/℃(0~50℃) |
|||
Vibration |
10~500Hz, 5G 10min./1 cycle,period for 60min. each along X,Y,Z axes
|
|||
Safety&EMC |
Safety standards |
EN61347-1 EN61347-2-13 (EU) & UL8750 UL1310 (US) |
||
Withstand voltage |
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC (EU) & I/P-O/P:1.5KVAC(US) |
|||
Isolation resistance |
I/P-O/P:100MΩ/500VDC/25℃/70%RH |
|||
EMC EMISSION |
EN55015 EN61000-3-2 ,3-3 (EU) & FCC Part 15 B (US) (≥60% loading) |
|||
EMC Immunity |
EN61000-4-2,3,4,5,6,11, EN61547 |
|||
Others |
Net Weight |
0.9KG |
||
Dimension |
277x78x25mm (LxWxH) |
|||
packing |
Carton size: 300*280*215mm; 20PCS/CTN |
|||
Notes |
1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation . 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. |
Mechanical Specification |
Connecting Diagram |