Product Overview
Description
Model
|
RFL-A3000D
|
|
Optical Parameters
|
|
Nominal Output Power (W)
|
3000
|
|
Operation Modes
|
CW/Modulated
|
|
Polarization Orientation
|
Random
|
|
Output Power Tunability(%)
|
10~100
|
|
Emission Wavelength(nm)
|
915±10
|
|
Output Power Instability(%)
|
<3
|
|
Modulation Frequency(Hz)
|
50~5k
|
|
Pilot Light Power(mW)
|
0.25~1
|
|
Output Cables Parameters
|
|
Output Header Type
|
QBH
|
|
Fiber Core Diameter(μm)
|
600
|
|
Minimum Bending Diameters
|
≥400
|
|
Half Angle of beam divergence(rad)
|
≤0.22
|
|
Delivery Cable Length(m)
|
20(Customizable)
|
|
Electrical Parameter
|
|
Power Supply
|
AC 380V±38, 50/60Hz, TN-S
|
|
Control Mode
|
Hyper Terminal/RS-232/AD
|
|
Other Parameters
|
|
Dimensions(W×H×D)(mm)
|
650×950×980
|
|
Weight(kg)
|
<150
|
|
Operating Ambient Temperature (℃)
|
10~40
|
|
Humidity (%)
|
<70
|
|
Storage Temperature (℃)
|
-10~60
|
|
Cooling Method
|
Water Cooling
|
|
Power consumption
|
22KW
|
|
The water temperature setting of cooling system:
a) summer(Ambient temperature is higher than 30℃)25±0.5℃.
b) winter(Ambient humidity temperature is lower than 30℃)22±0.5℃.
Coolant requirements:
a) The cooling water is pure water. It is recommended to use pure drinking water;
b) In order to prevent mould growing that may lead to pipe blockage, we recommend to
add alcohol about 10% of the total volume.
c) When the ambient temperature ranging between -10 ℃ and 0 ℃ , user need to add
alcohol about 30% of the total volume, change alcohol every two years.
d) When the ambient temperature below -10℃, user must use dual-cooling water chiller,
and ensure continuity of work.
Other requirements for chiller:
a) When starting the cooling system for the first time, check the entire water system and
the joint for water leakage. The external water pipe must be installed and connected
according to the inlet (IN) and outlet (OUT) by the laser. Otherwise, the laser may not
work properly.
b) If you will not use the laser for a long time, water must be emptied from the product,
and then both the inlet and outlet must be blocked with the nuts we provide. Failure to
do so may lead to permanent equipment damage.
c) When the customer is empting the cooling water of the laser water-cooling system,
please use compressed gas with pressure less than 0.5mpa, otherwise it will cause
irrepairable damage to the chiller.
Our Services
1) Free Pre-Sales Consulting / Free Sample Marking
2) Strict Quality Control of Production
3) 5-7 Days Quick Delivery
4) 1 Year Quality Guarantee
5) 12 hours Quick Feedback & After-Sales Service
6) Quick Back-up Parts Available & Technical Assistance
7) Free Training Service
8) Special Designing, Customized, OEM Order is accepted