Analyzer Aging Testing Equipment Aging Cabinet For 18650 Lithium Battery

Share on:


Price:
Price in USD:Details

Quantity:


Product Overview

Description


1.png


 


Analyzer Aging Testing Equipment Aging Cabinet For 18650 Lithium Battery


 


SPECIFICATION.png


Description


This charge-discharge test equipment is mainly used for lithium battery charge-discharge cycle test, the test items include: battery charge protection voltage, discharge protection voltage, capacity, etc. The device has four test steps: charging, discharging, shelving, and cycling. By editing the corresponding steps, the battery can be tested in accordance with the set process.


 


Basic performance


*1. Charge and discharge function:


It has the function of constant current and constant voltage charging and constant current discharge, charging and discharging the battery, and recording the battery capacity.


*2. Charge and discharge interface:


Fully meet the requirements of charging and discharging the same port and charging and discharging separate ports of the battery pack, that is, 2 wires (P+ P-) and 3 wires (P+ P- C-). At the same time, it can age the power tool battery (CH+ P+ P-) with positive plate charge protection and negative plate discharge protection.


*3. Check the voltage protection:


By charging and discharging the battery, it can be detected whether the battery's charge protection and discharge protection are working.


*4. Security protection:


Anti-reverse connection protection function; voltage upper and lower limit setting protection; safe discharge current protection;


*5. Online mode


If the instrument is single or less than 5, it can be connected to the PC through the serial port;


In the network connection mode for more than 5 units, the PC computer only needs to provide a network port to control less than 60 instruments.


*6. Control system


The software system adopts the classic and mature C/S mode. There are two communication methods: serial port and network. The serial port can realize the accurate communication of several instruments in a short distance, and the network can realize the accurate communication of multiple instruments in a long distance.


*7. Management software


Based on the Windows operating interface, the SQL database is used to store test data, which greatly facilitates the staff to query and export data online. According to the battery bar code, time, and device number, the charge and discharge aging curve can be viewed, and the curve can be exported.


 






























































































































Input Power Ac 220V ±10% / 50Hz
 Voltage Measuring Range 10~100V
Accuracy ±(0.2% Of Reading + 0.2% Of Range)
Current Charging Range 200~20000ma
Charging Accuracy ±(0.2% Of Reading + 0.2% Of Range)
Discharge Range 200~40000ma
Accuracy ±(0.2% Of Reading + 0.2% Of Range)
Charge Constant Voltage Cut-Off Current Minimum 200ma
Capacity Accuracy ±1
Power Discharge Power <=4000W
Time Inspection Time Receive In Real Time<2S
Timer Range 0~999
Data Recording Interval 5S
Mid-Position Machine Version 1.1series
Charge Charging Mode Constant Voltage Constant Current Charge
Cut-Off Condition Voltage, Current, Relative Time, Overcharge Protection
Discharge Discharge Mode Constant-Current Discharge
Cut-Off Condition Voltage, Relative Time, Over - Discharge Protection
Circulation Cyclic Measurement Range 1~999times
Number Of Steps In a Single Cycle 100
Voltage And Current Detection Sampling Four Wire Sampling System
Database Adopt Sql Database To Manage Test Data
Communication Mode Of Upper Computer Based On Tcp/Ip Protocol, Serial Port
Data Output Mode Excel,Txt,Graph
Communication Interface Network Port
Number Channels Per Cabinet Single Channel
Cabinet Size W*D*H:800*520*1370(Mm)
Battery Space Size W*D*H:700*400*420(Mm)

 


 


 


 


 