Share on:
Optional Features | ||
Register Sealed type: | Dry type | |
Accuracy: | R=80 ; 100 | |
Size: | 15~50mm. | |
Non return valve. | ||
Reed switch option. | ||
Thread end type: | BSP /NPT.Working Conditions | |
Water temperature: | 0.1℃~40℃ for cold water meter. | |
Water pressure : | ≤1.6Mpa ((16 bar). |
Magnet Position | Liter /Pulse |
* 0.0001 | 1 |
* 0.001 | 10 |
* 0.01 | 100 |
* 0.1 | 1000 |
DN(mm) | 15 | 20 | 25 | 32 | 40 | 50 | |||||||
Size(inch) | 1/2" | 3/4" | 1" | 1-1/4" | 1-1/2" | 2" | |||||||
Q4(l/h) | 3125 | 5000 | 7875 | 12500 | 20000 | 31250 | |||||||
Q3(l/h) | 2500 | 4000 | 6300 | 10000 | 16000 | 25000 | |||||||
R=80 | Q2(l/h) | 50 | 80 | 126 | 200 | 320 | 400 | ||||||
Q1(l/h) | 31.25 | 50 | 78.75 | 125 | 200 | 250 | |||||||
R=100 | Q2(l/h) | 40 | 64 | 100.8 | 160 | 256 | 400 | ||||||
Q1(l/h) | 25 | 40 | 63 | 100 | 160 | 250 | |||||||
Max.Reading(m3) | 99.999 | 99.999 | 99.999 | 99.999 | 99.999 | 99.999 | |||||||
Min.Reading(Liter) | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | |||||||
Max.Pressure(Bar) | 16 | 16 | 16 | 16 | 16 | 16 | |||||||
Pressure Loss | 63 | ||||||||||||
Max.Temperature | T=50 | ||||||||||||
Pulse Output Option | Vmax=24V | ||||||||||||
Imax=100mA | |||||||||||||
Pmax=2W |