Share on:
Item | Vortex flow meter |
Model | TEMGB |
Application range | (1)Gas; (2)Liquid; (3)Steam |
Pipe size | DN15-DN300 |
Connection | Flange or Wafer connection |
Measured Value | Flow Rate, Volume flow |
Compact version converter | N Type: Pulse output without local display |
A Type: 4-20mA Output without local display | |
B Type: Local Display; Lithium Battery Power; No Output (Battery Part No.: ER26500) | |
C Type:Local Display; 24VDC Power; | |
Optional Function: (1) Backup Power Supply: Lithium Battery (2) Modbus RS485 (3) Pulse Output | |
Accuracy | For Liquid:1.0% of rate For Gas and Steam:1.5% of rate |
Pressure | 1bar/14.5 psig |
Temperature | +10...+30°C/+50...+86°F |
Electrical conductivity | ≥300μS/cm |
Measurement Ratio | Standard–10:1 |
Flange material | SS304 |
Sensor material | SS304 |
Converter Housing | Standard: polyurethane coated die-cast aluminum |
DN | L(mm) | H(mm) | D(mm) | ||||||
Clamp Type | Flange Type | Clamp Type | Flange Type | Clamp Type | Flange Type | ||||
DN15 | 70 | 180 | 335 | 240 | 15 | 15 | |||
DN20 | 70 | 180 | 335 | 240 | 20 | 20 | |||
DN25 | 70 | 200 | 335 | 240 | 25 | 25 | |||
DN40 | 70 | 200 | 335 | 247 | 40 | 40 | |||
DN50 | 80 | 200 | 335 | 252 | 50 | 50 | |||
DN65 | 80 | 200 | 345 | 260 | 65 | 65 | |||
DN80 | 100 | 200 | 355 | 268 | 80 | 80 | |||
DN100 | 120 | 235 | 365 | 280 | 100 | 100 | |||
DN125 | 140 | 270 | 382 | 290 | 125 | 125 | |||
DN150 | 160 | 300 | 395 | 305 | 150 | 150 | |||
DN200 | -------- | 360 | -------- | 332 | -------- | 200 | |||
DN250 | -------- | 400 | -------- | 355 | -------- | 250 | |||
DN300 | -------- | 400 | -------- | 380 | -------- | 300 |