Range | MPa | -0.1MPa…0kPa~10kPa…100MPa | |||||
Form of pressure | G、A、S | ||||||
Output signal (mA) | 4 mA ~20 mA (HART protocol can be superimposed), RS485 (4 mA~20 mA signal can be output at the same time) 0~5V (0 ~10) three wire system | ||||||
Accuracy level | 0.1(customized) | 0.25 | 0.5 | ||||
Nonlinear (FS%) | ≤0.1 | ≤0.2 | ≤0.4 | ||||
Hysteresis, repeatability (FS%) | ≤0.05 | ≤0.05 | ≤0.1 | ||||
Zero and sensitivity temperature drift (FS / ℃) | ≤0.015 | ≤0.03 | ≤0.05 | ||||
Long term stability (FS / year) | ≤0.1 | ≤0.2 | ≤0.5 | ||||
Operating voltage (VDC) | +15~ + 30 (calibration value is + 24) | ||||||
Field display | 4Bit LED or LCD | ||||||
Compensation temperature (℃) | 0~+50(≤200kPa),-10℃~70℃(>200kPa) | ||||||
Operating temperature (℃) | -40~ + 85, - 20 ℃ ~60 ℃ (explosion proof) | ||||||
Overload capacity (%) | ≤200(<10MPa );≤150(≥100MPa) | ||||||
Load resistance (Ω) | R=(U-12.5)/0.02-RD Where: u is the power supply voltage and RD is the internal resistance of the cable | ||||||
Response time (10% - 90%) ms | ≤1 | ||||||
Measuring medium | Fluids compatible with 304, 316L or ceramics | ||||||
Diaphragm material | 316L, titanium alloy or ceramic are available | ||||||
Shell material | 3046063 aluminum alloy | ||||||
Interface | 304326l optional | ||||||
Explosion proof grade | Intrinsically safe: ex D IIC T5 GB | ||||||
Protection level | IP66 |