3 phase 100a Automatic Transfer Switch

 

1.1.jpg

 

#

Product Description

Automatic Transfer Switch normal operating conditions:

1.The ambient temperature shall not be higher than +40℃, or lower than -5℃, and the daily average shall not exceed +35℃.

2.The altitude of installation site shall not exceed 2000m.

3.Relative humidity shall not exceed  50% at the ambient temperature of +40℃ , a higher humidity is allowable at a lower temperature, the average maximum relative humidity is  90% in the wettest month at a monthly average minimum  temperature of + 25 ℃,and special measures shall be taken for the condensation on surface of product due to temperature change.

4.Pollution class: class Ⅲ .

5.In place of no intense vibration and impact,  no harmful gas corrosive and disruptive to the insulation, no sever dust, no conducting microparticle and explosive substance, no high electromagnetic interference.

 

 

Automatic Transfer Switch Main Speciality:

1.Reasonable structure,  small volume, nice appearance, provided with protective shield, safer and more  reliable power supply.

2.Complete protective functions, including short circuit, overload, open phase and loss-of-voltage protection.

3.Reliable remote double-break with EPS fire protection power supply interface DC12-24V.

4.Noiseless, energy saving ,  simple  installation ,  easy operation, reliable and stable performance.

 

Automatic Transfer Switch Technical Date:

 

 

Rated Working Current10A16A20A25A32A40A50A63A
Rated Working VoltageAC400V
Controling VoltageAC230V
Rated Short Circuit Breaking Capacity3KA
Rated Short Circuit Making Capacity3KA
Rated Insulation VoltageAC500V
Transfer Time≤3S
Frequency50/60HZ
ATS LevelCB Class
StandardIEC60947-1

 


 

Automatic Transfer Switch Pictures Show:

1.jpg

 

2.jpg

 

3.jpg

 

4.jpg

 

 

Automatic Transfer Switch Operation:

        The inlet and outlet line & neutral line of normal and ready  power shall be properly wired according to actual requirement of circuit design. The outlet  terminals of the two circuit breakers shall be connected in parallel with accordant phase order  (refer to the wiring diagram).

        When manual operation is required for the transfer switch,as for FTS-63 type ,button switch shall be put to manual position first, then transfer or normal or ready power can be made by turing the handle, as for FTS-63 type ,  transfer or normal or ready power can be made only by pushing manual / auto button until the manual indicator is on, when the control mode is in automatic position,the transfer will enter automatic work condition and the normal power will operate preferentially.

        When the transfer switch is wired according to wiring diagram , after power on, if the normal and ready power are in good condition,the indicator  (red)  of normal or ready power will be on and the transfer switch will work normally.

 

 

.jpg

 

Automatic Transfer Switch Dimension:

 

.jpg

Packaging & Shipping

Automatic Transfer Switch Packing:

 

1.    Standard export box package : 36.5/32.5/27cm3 

2.   Delivery Time: 10-15 days for batch goods.

 

Automatic Transfer Switch Shipping:

 

1.    Shipment port:SHANGHAI/NINGBO

2.    By Air or by Sea for batch goods,Airport/ Port receiving;

3.   Customers specifying freight forwarders or negotiable shipping methods!

 

 

shipping.jpg

0.0218 s.