♦ Parameter

 

Type: GSS5810-OC-RAG10000Z1-2M                     Readout Model: Contact                             Signal Output: NPN
Package: SMD                                                            Brand: GTEACH                                              Pulses: 10000
Working Principle: Incremental                             Operating System: Photoelectric              Installation Form:  Axonia
Axonia: Synchronous Flange                                  Transport Package: 1 PCS Per Box

 

♦ Products

 GSS5810-750-1GSS5810-750-2

♦ Recommend

 GSK 1024 ppr ABZ phase Half empty encoder diameter 38mm hollow shaft 8mm type optical incremental rotary encode 1024 pulse
GSK 1024 ppr ABZ phase Half empty encoder diameter 38mm hollow shaft 8mm type optical incremental rotary encode 1024 pulse

♦ Specification

Item

Diameter 58mm shaft 10mm type incremental rotary encoder

Resolution(P/R)

10000

 

Output Phase

A,B,Z phase (Line driver: A,–A,B,–B,Z,–Z phase)

Output Type

NPN , Voltage, Push-pull(Totem pole), Line driver 5V

Shaft size

10mm

Electrical

Supply

Voltage

5-24VDC (Line driver output ONLY 5V, 8-24V can be customized)

Current

consumption

Max.80mA (Disconnection of the load), Line drive output: Max. 50mA  (Disconnection of the load)

Response

frequency

Max. 200Khz

Allowable revolution

Max. 3000 rev/min

Rise/Fall

time

Max. 1μ's(other output), 0.5μ's (Line driver output)

Mechanical

Starting torque

Max. 50gf.cm (0.005N.m)(*1) 90gf.cm (0.009N.m) (*2)

Rotor inertia

Max. 30g.cm2(3*10-6kg.m2) (*1) 60g.cm2(6*10-6kg.m2) (*2)

Shaft loading

Radial: Max. 35N   Thrust: Max. 25N

Mechanical

Speed

Max. 5000 rev/min  (*3)

Environmental

Ambient temperature

-10~70 (at non-freezing status), Storage:-25~85

Ambient humidity

35~85%RH, Storage: 35~90%RH

Protection

IP64 (IEC standard)

Vibration

1.5mm amplitude at frequency of 10-55 Hz in each of X,Y, Z direction for 2 hours.

Shock

Max. 70G

Unit weight

Approx: 300g

Cable

5mm, 5P, Length: 2m, shield cable (Line driver output: 5mm, 8P)

Connection

Cable outgoing type

Insulation resistance

Min. 100MΩ (at 500VDC)

Dielectric strength

750VAC 50/60Hz for 1 minute (Between all terminals ad case)

Approval

CE  ROHS

 (*1) Standard type (IP52)

(*2) Standard type (IP64)

(*3) Mechanical speed > Allowable revolution, Please take allowable speedas standard when use

Drawing

5810-790-1

♦ Pin Assignment

------------------------------------------------------------------------------------------------------------------------------------------------------

Conditions and terms

1. All of the products are brand new, top quality components, absolutely no used items

2 .The pictures are for reference only. Exact specifications should be obtained from the datasheet.

3. Prices, specifications, and availability of all items are subject to change without notice.

 

 Payment Terms

1. We accept payments made by TT, PayPal, and L/C

2. Since you made the payment successfully, you can send us the Reference NO or MTCN.

 

Shipping

1. We will ship the items within 3-15 working days after the payment is reached.

2. We ship to you by Express, by sea, by air according to the PI.

3. Any import fees or charges are the buyer's responsibility.

 

Warranty

 Warranty is available based on the following points:

1. Quality guaranteed for one year.

2. If the items you purchase from our company are not of perfected quality, that is they don't work electronically to manufacturers specifications, simply return them to us for replacement or refund.

3. If the items are defective, please notify us within 3 days of delivery.

4. Any items must be returned in their original condition to qualify for a refund or replacement.

 

Caution for using


1.Installation
this unit consists of precision components. If you drop this unit, it may lose the function.
Please treat this product carefully.
When you install this unit, if eccentricity and deflection angle are larger, load is applied to the
Shaft it may shorten the life cycle of this unit.
Do not put strong impact with hammer, etc when insert coupling into shaft.

2. for using
do not cut or connect circuit when power is ON. It may cause damage to the unit.
When the power source is Switching Power, it may cause surge. Install a surge absorber in
Power line. Wire should be shorter in order not to be influenced by noise.
Do not splash water, oil etc, cover the protecting hood when necessity.

3. Environment
Please do not use this unit with below environment, or it may cause malfunction.
Place where this unit or component may be damaged by strong vibration or impact.
Place where there is a lot of flammable or corrosive gases.
Place where strong magnet field or electric noise occurs.
Place where is beyond of the rated temperature or humidity.
Place where strong acids or alkali nearby.
Place where there is the direct ray of the sun.

4. Vibration and Impact
if a big impact or strong vibration applies to the product it may cause pulse errors. Be sure that
when installing this unit.
Encoder with high resolution can be easily affected by vibration, therefore tighten fixing bracket
When installing this unit.

5. Wire connection
Do not pull out the wire with over 30N strength after fixing the unit and wiring the cable.
If wire encoder cable with high voltage line or power cable in the same conduit, it may cause a
Malfunction or mechanical problem. Please wire it separately or use separated conduit.