2020 Electrical heating mat indoor heating system under tile electric heat cable in home T mat

Share on:


Price:
Price in USD:Details

Quantity:


Product Overview

Description



Product Description




Electrical heating mat in heating system under tile in home




Introduction

T-mat underfloor heater electric heating mat uses a twin conductor heating cable for easy of installation and very low EMF. The mat thickness of only 4.0 mm enables underfloor heating installations into most quality two-part adhesive with a minimum increase in floor height.



Features

150 w/㎡ 200 w/㎡
Twin conductor heating cable
Very low EMF
Only one cold tail for ease of Installation, 2.5 meters
Thin, only 4.0 mm
Self adhesive
Flexible
100% screened







Application

♦ T-mat underfloor heater electric heating mat is designed for installation into thin adhesives, leveling compounds or thin screed beds beneath tiled and wooden floor finish.
♦ 150 w/㎡ heating mats are suitable as a primary heating source providing you have adequate insulation. These are our most commonly used mats for kitchens, dining rooms, large bathrooms and most other areas with tiled floors.
♦ 200 w/㎡ heating mats are generally used in areas where high heat loss is a problem, such as conservatories. These mats are only suitable under tiled floors, giving a 25% faster warm up time.
♦ Renovated and thin floors
♦ Under tile
♦ Under timber

MOQ: 20 PCS
OEM and ODM available



Installation instructions




Products' property:

Underfloor heater electric heating mat can produce different power as customized, easy installation and durable, no need to maintain it. One cold line that connects hot line is about 4 m, the annular shape of cable can create max comfort for room. It can be used for different flooring, such as tile, stone, marble etc.



Notice! Please make sure the cold lead is at least 10 cm away from the heating cable, otherwise, it will be damaged from high temperature.





1. Underfloor heater electric heating mat could be easily adapted and shaped to fit your all room, no matter your room is square or other shapes, but please remember: Do not cut the heating wire!





2. Underfloor heater electric heating mat can be turned at walls by cutting the mesh and rotating the roll. The mat can continue to be rolled out making sure to maintain a 50 mm gap between. The heating mat must be guided around fixed objects such as toilets, basins, cupboards etc. For gaps where a 500 mm mat cannot be fitted (or around fixed obstacles), remove and discard the mesh backing from the cable and lay the cable maintaining a spacing not less than 50 mm apart between centers.





Remark:

1. Cables cannot be cut!
2. Cutting and Turning the mat!
3. All electric connections must be performed by a fully qualified and certified electrician!


Important: measure the resistance four times during the installation process
Remember to always measure, verify and record the actual resistance throughout the installation process (out of the box, after installation, after thin set cement or self-leveler application and after installation of floor tiles).



Install underfloor heating mat step by step:


Design the Installation
Step 1: Measure the heated area
Determine the heated area of the floor where there are no permanent fixtures or furniture such as showers, toilets, vanities, or cabinets. Measure the heated area of the floor.
For example, in Figure 3, the area of the bathroom is 8.75 m2. When you subtract the area of the vanity, shower and toilet, the total heated area is only 6.45 m2.
Step 2: Determine the power supply voltage
Make sure the supply voltage was 230 V.
Step 3: Plan the design
Determine the optimum floor heating mat layout for your heated area to ensure coverage. Select a spot for the thermostat in the wall above the heated area where it can be reached by the 2.5 m cold lead on the Heating mat, and the 3.0 m floor temperature sensor. Please refer to Figure 4.


Installation
Important: Tools and materials required
You will require the following items to install and test the floor heating system:
·Scissors
·Utility knife
·Wire strippers
·Tape measure
·Screwdriver
·Multi meter
You will also need the appropriate tools and materials to install your particular floor. These will likely include products like self-leveling mortar, thin-set mortar, backer board, tile, a notched trowel, and any other tools for your specific floor.
Follow these steps to ensure a successful Heating mat installation.

Step 1: PLAN LAYOUT

Step 2: TRANSFER LAYOUT TO FLOOR

Step 3: INSTALL SENSOR

Step 4: PREPARE SUB FLOOR SURFACE

Step 5: MEASURE THE RESISTANCE (THE FIRST TIME)

Step 6: BEGIN LAYING THE heating mat

Step 7: MEASURE THE RESISTANCE (THE SECOND TIME)

Step 8: INSTALL FLOOR COVERING

Step 9: MEASURE THE RESISTANCE (THE THIRD TIME)

Step 10: INSTALL THE TILE

Step 11: CONNECT POWER SUPPLY AND THERMOSTAT

Step 12: MEASURE THE RESISTANCE (THE FOURTH TIME)

Step 13: RECORD INFORMATION AND AFFIX LABELS
Step 14: ENJOY THE COMFORT OF heating mat






Product Advantages


Self adhesive
Perfect after-sale service
Factory price
Ease of installation

All mat choose the top quality raw material to process and produce, environmental protection and saving energy, for example the high quality fluoropolymer insulation, high-intensive outer jacket, export the cable heating conductor terminals, for the heating cable and cold lead coupling/connection, we can provide two kind of manufacturing processes, one is use heat shrinkable tube, the other one is machine injection mold.







Certifications




Related Products


Save energy underground heating system electric heating cable

T-cable underground heating system is designed to be as thin as possible, only 3.6 mm, we have two kinds of output power, ensure the economic and energy saving and decrease the floor level to the maximum extend.



Roof and gutter deicing cable heat tracing system

LSR heat tracing system is ideally used for process temperature maintenance and frost protection of regular diameter pipelines, tanks, valves, flanges, roof & gutter de-icing, snow melting and other application where low temperature is needed. It is suitable for hazardous area, also non-hazardous area and corrosive area with fluoropolymer outer jacket. UV stabilized thermoplastic elastomer outer jacket is provided to cover the braid for wet applications and exposure to the sun.



HOT SALE PRODUCTS





Packing & Delivery


Packing: usually packed in white box first, and then packed into carton box. If it is big order with large quantity, we can provide the customized service, such as the cable marking, adhesive tape with logo, individual color box or other order requirements.

Shipping: customer can choose the carton box packing by pallet or without pallet; the delivery method can be by sea, by air, by train, by truck or by international express.





Our Service




Our Company










FAQ




1.5742 s.