Share on:
[Model number]:JN5-60
[Gross Weight]: 3.8KG
[Power]: ≤115W
[Packaging Size]: 45*45*21cm
[Voltage]: 110V/240V 50 - 60HZ
[Capacity]: 60 chicken eggs
50 duck/turkey eggs
80 bird eggs
30 goose eggs
Incubating list (unit: day)
eggs | Start shell breaking | Start coming out | Coming out together | Finish |
Chicken | 19 | 20 | 20-21 | 21 |
Duck | 26 | 27 | 27-28 | 28 |
Goose | 28-29 | 28-30 | 29-31 | 32 |
characteristic
It is suitable for the families and specialized households to incubate chickens, ducks and geese, etc. This machine is produced according to the testing requirements of CE technology standard of EU, and has good reputation from the peasants in the rural area of eastern European countries. The machine has the characteristics of strong practicality, simple operation and long service life, etc.
I. Incubation Temperature Control
Poultry | Number of days | Incubation period | Hatching period | Hatching egg weight G | ||
Temperature ℃ ±0.5 | Humidity % | Temperature ℃ ±0.5 | Humidity % | |||
Chicken | 21 | 38 | 55-75 | 37.5 | 65-85 | 100-120 |
Dove | 18 | 38.5 | 55-75 | 37.8 | 65-85 | 30-40 |
Local chicken | 21 | 37.9 | 55-75 | 37.5 | 65-85 | 45-55 |
II. Humidity Control
It requires different relative humidity in different period of incubation. The relative humidity shall keep within 55%~60% at the earlier stage of incubation to ensure even heating for embryo, which is good for formation of allantoic fluid and amniotic fluid, the relative humidity shall keep within 30%~55% at the middle stage of incubation, which is good for evaporation of water, the relative humidity at the last stage of incubation shall be increased to 65%~75%, as high relative humidity is good for poult to hatch, when above 20% of poult hatches, the relative humidity shall keep at 75%~85%
III. How to use:
1. Cleaning and sterilization before incubation: wash and clean the incubator, then suffumigate it with potassium permanganate and formalin.
2. Incubation equipment inspection before incubation: check all of the parts completely and observe whether the fan rotation device works normally and whether all of the components are in good condition, then adjust the temperature and feed water to the tank. Make a 12-24 hours’ trial again when the incubator reaches temperature and humidity requirement, if the incubator works normally, it can be put into running.
3.Choose and store fresh egg within 5 days (7 days at most) as hatching egg, as for the egg stored for more than 5 days, 4% less the incubation rate and 30 minutes prolonged incubation period for one more day storage. The proper temperature for hatching egg storage is 12℃~16℃.The smaller side shall be put upside during hatching egg storage.
4. Notes for off-tray period: The process to remove from egg tray to hatching tray is called off-tray, the chick embryo usually removes off the tray at an age of 18-19 days. It shall be placed gently during off-tray, it’s best to lay to single layer. It also removes to hatching tray 3 days earlier than incubation period for other poultry.
Menu Code Selection:
Code | Description | Setting range | Factory set | Unit |
HU | Heating power parameter | 1-90 | - |
|
HD | Heat preservation power parameter | 1-80 | - |
|
LS | Lower limit set | -9.9~HS | - | ℃ |
HS | Upper limit set | LS~99.9 | - | ℃ |
CA | Temperature correction | -5~+5 | -- | ℃ |
AH | Factory set, not adjustable | 0-15 | - | ℃ |
AL | Factory set, not adjustable | 0-15 | - | ℃ |
IV.Safety Notice
1.Only the power supply marked on the incubator can be used;
2.Don't put incubator near wire,the power line of incuabtor should be placed at where won't be stepped on or make people trip and fall.
3.Make sure that the socket and extension line in use don't overload,otherwise it may cause fire or electric shock.
4.Pls cut off the power supply if incubator is smoking ,smells abnormal or make unusual noise,then contact the agency or maintaince centre to solve that problem.
5.Don't touch the power line by wet hand,or it may cause electric shock;
6.This incubator can't be exposed to rain and sunshine;
7.Make sure that power supply is switched off before cleaning the incubator;
8.The incubator shall be placed in room where had good airbut no vibratory equipment,it can't be placed in room with fast air movement or room with harmful and noxious chemicals and other pollutants.
9.Don't block the air-bleed hole when the incubator is in work condition.