Share on (10000016181592):
item | value |
Place of Origin | Italy |
Technical Data: | Power supply 110 – 120 V / 50 – 60 Hz 200 – 240 V / 50 – 60 Hz Admissible voltage fluctuations ±10% Max. power consumption 12 A at 110 – 120 V 8.0 A at 200 – 240 V Vacuum pump data Max. power consumption: 250 W Final vacuum: < 50 mbar Only tested pumps should be used. Dimensions of Depth: 465 mm closed furnace Width: 320 mm / 390 mm (with cooling tray) Height: 550 mm Dimensions of Diameter: 90 mm firing chamber Height: 80 mm Max. firing temperature 1,200 °C Weight 18.3 kg Safety information The furnace is built according to the following standards: – IEC 61010 – UL and CAN/CSA Radio protection / EMC tested Electromagnetic compatibility |
Features: | * FPF function: Fully automatic Press Function for optimum press results. * Programs are optimally coordinated with Ivoclar Vivadent materials. * QTK2 muffle technology with SiC bottom reflector for homogeneous heat distribution. * Colour touch screen and proven membrane-sealed keypad for easy operation. * Electronic press drive with force sensor produces high-quality press results. No compressed air connection required. * Crack Detection System detects cracks in the investment ring. * Easy and automatic temperature calibration at two reference points (ATK2). * Simple software update via USB flash drive. * Remote diagnosis function via data file for optimum support by a service centre. * Broad range of programs: 300 individual firing and 20 individual press programs. * Power Saving Technology for power-saving operation. |