Alkaline Battery Pack

Share on (1072187520):


Price:

Quantity:


Product Overview

Description


 


 


1. Applicability


 


This specification is applicable to Golden Queen battery produced with LR6 zinc-manganese super alkaline battery.


 


2. General


 


2.1 Type designation


 


IEC LR6


 


JIS AM-3


 


ANSI AA


 


2.2 Reference Document


 


IEC 60086-1:2007---Primary Batteries- Part 1: General


 


IEC 60086-2:2007---Primary Batteries- Part 2: Physical and electrical specifications


 


IEC 60086-5:2005---Primary Batteries- Part 5: Safety of Batteries with aqueous electrolyte


 


2.3 Chemical system


 


Zn/KOH/MnO2 (Mercury & Cadmium Free)


 


2.4 Nominal voltage: 1.5 V


 


2.5 Weight: approximate 23.1g


 


2.6 Dimension (mm) Min Max


 


Φ:………… 13.9 14.3


 


A:………… 49.4 50.4


 


B:………… 49.2 50.2


 


C:………… 9.0 9.4


 


E:………… 0.1 0.5


 


F:………… 5.3 5.5


 


G:………… 1.2 1.8


 


2.7 Heavy metal contents


 


Mercury max 1ppm / battery


 


Cadmium max 10 ppm / battery


 


Lead max 20 ppm / battery


 


2.8 Capacity


 


Approximate 2800mAh (25mA, 20°C±2°C, 0.8V cut off )


 


3. Appearance


 


The products shall be free from dents, scratches, corrosion, contamination, or disfigurations, which affect service and sale ability.


 


4. Electrical Characteristics (3.9Ω, 0.3S, 20±2°C)


 


/ OCV(V) CCV(V) short-circuit current(A)


 


Initial 1.60 1.50 12


 


Storage 1year 1.57 1.46 10


 


5.Discharge Capacity (20±2°C, RH: 45%-75%)


 


load 24Ω 250mA 3.9Ω 1.5w 1000mA 10Ω 43Ω


 


discharge mode 15s/min,8h/d 1h/d 1h/d Pulse_A* Pulse_B* 1h/d 4h/d


 


end voltage 1.0V 0.9V 0.8V 1.05V 0.9V 0.9V 0.9V


 


Initial 46h 8h 7.8h 100 times 500 times 20.5h 94h


 


storage 1 year 42h 7h 7.0h 90 times 450 times 19.0h 90h


 


Pulse_A* :(1500mW2s,650mW28s)10T/h,24h/d


 


Pulse_B*: 10s/m,1h/d


 


*Discharge curve see appendix 1


 


6. Leakage Resistance


 


6.1 Over discharge leakage test


 


Test conditions: 20±2°C & RH 60±15%, 10Ω continuous discharge 48h.


 


Number of test samples: 9 batteries


 


Requirement: No visible leakage; No explosion.


 


6.2 High temperature leakage test


 


Test conditions: store 20 days under 60±2°C, then store 4~24h under standard environment.


 


Number of test samples: 24 batteries


 


Requirement: No visible leakage; No explosion.


 


7. Security Characteristics


 


7.1 The delivered batteries stored under normal non-air conditioned environments shall not have electrolyte leakage during the guarantee period.


 


7.2 Over discharge:


 


When the batteries are discharged under the conditions of specified load, until the on-load voltage falls to 0.6 V, no leakage or explode shall occur, in accordance with IEC Publication 86-1 requirement.


 


7.3 External short circuit:


 


The terminal of an un-discharged battery is connected by wire. The circuit is completely for


 


24hours or until the case temperature has return to environment. with the course, the battery will not leakage or explode.


 


7.4 Incorrect installation:


 


4 pieces of battery are in series connected and one of them is under incorrect polarity for 24 hours or until the case temperature has return to environment. with the course, the battery will not leakage or explode.


 


7.5 For further Security acceptance tests are to be agreed between BODAWUTONG and purchaser.


 


8. Expiry Period


 


5 Years


 


9. Expiry Date Marking


 


9.1 Production date marked on the bottom plate of finished cells. for example: 2012-02 means produced on Feb. 2012.


 


Shelf life 5 years marked on bottom of sticker label.


 


9.2 For private label, can mark according to customer's requirements.


 


10. Package


 


The package can be packed according to customer order’s detail requirement.


 


 


0.1837 s.