Description



Glove Box for Perovskite Solar Cells

Technical Description
This glove box is suitable for the research and production of perovskite solar cells.

Water oxygen index: less than 0.1 ppm
Leakage rate: 0.001vol%/h

Model: TOB-GLOVE BOX(1800+1220/750/900)
This is a compact glovebox that connects a two-station glovebox to a single-station glovebox via a T-transition chamber. It has single-side operation, PLC control and touch screen operation functions. Integrated single column purification unit, vacuum pump, holder, one with angled operating surface and removable safety glass front window, etc.
Under standard conditions, that is, 20℃ constant temperature, a standard atmospheric pressure, 99.999% inert air source, water oxygen index is less than 0.1 ppm.

Function of glove box

Closed circulation
The inert gas in the glove box is closed by the circulating fan and purifier to remove water and oxygen constantly.
Automatic controlled regeneration
Dehydrating and deoxygenating materials can be regenerated, and the regeneration process is controlled by the program.
Automatic cleaning
Air displacement in the glove box is accomplished by an automatically controlled cleaning valve.
Tank pressure control
The pressure inside the glove box is automatically controlled by PLC. The working pressure can be set freely within +/- 15mbar. When it exceeds +/- 16mbar, the system will start automatic protection.
Vacuum pump automatic control
The vacuum pump must be automatically started when the system needs it.

Main Components
2 glove boxes in 304 stainless steel, acid resistant, 3 mm thick
2 small vacuum transition chambers made of stainless steel, diameter 150mm, length 300mm, left and right
1 large vacuum T-shaped transition chamber made of stainless steel, diameter 360mm, length 700mm, middle
1 small vacuum T-shaped transition chamber made of stainless steel, diameter 150mm, length 900mm, middle
1 front window with 2 glove ports
1 front window with 4 glove ports
3 pairs of butyl rubber gloves
2 sets of lighting systems
2 high performance circulating fans
2 sets of purification systems
2 vacuum pumps
1 quick-change organic solvent adsorber
2 sets of PLC control and touch screen operating system
Several blind flanges
2 in-box power cords
2 sets of water analyzers
2 sets of oxygen analyzers
2 sets of ultra-clean filtration systems
2 sets of temperature control systems
2 bracket casters
2 foot switches


(1)Box
Box
Material: 304 stainless steel, thickness 3mm
Inner surface: brushed stainless steel
External surface: spray paint, white
Nominal size of box 1 Length: 1800mm, depth: 750mm, height: 900mm
Nominal dimension of box 2 Length: 1220mm, depth: 750mm, height: 900mm
The left side of the box is recessed and reserved for the coating machine interface
Front window
Flange window, one-piece molding, O-ring, vacuum seal, ultra-low leakage rate
Sloping windows, transparent tempered safety glass, thickness 8 mm
Glove port
material is aluminum alloy, O-ring seal, easy maintenance, and good sealing performance
Gloves
Butyl, 8" diameter. 32" length.
Filter
0.3 micron gauge, 1 gas inlet and 1 gas outlet
Shelf
stainless steel material, built-in 3 layers
Cabinet lighting
LED lights, installed above each glass window
Interface
Several spare interfaces, DN 40 KF, 1 power cord in the box (220V)
(2) Small Transition Chamber
Transition Chamber
Dimensions 150mm in diameter, 300mm in length, 100mm in length into the glove box
Material: 304 Stainless Steel
Surface: The inner surface is brushed, the outer surface is painted (white)
Appendix
Doors: Double doors (blue), button-down
Pressure gauge: analog display
Cabin Tray: 304 Stainless Steel
Control
Manual valve manual operation
(3) Large T-shaped transition Chamber
transition Chamber
Size: diameter 360mm, length 700mm
Material: 304 stainless steel
Surface: The inner surface is brushed, the outer surface is painted (white)
Appendix
Sliding Tray: 304 Stainless Steel
Doors: three doors, anodized aluminum material, thickness 10mm, vertical operation, with lifting mechanism
Pressure gauge: analog display
Control
Solenoid valve touch screen automatic operation
Function
Connect two glove boxes, the sample can be transferred from left to right or from the middle to both sides
(4) Small T-shaped transition Chamber
transition Chamber
Dimensions 150mm in diameter, 300mm in length, 100mm in length into the glove box
Material: 304 Stainless Steel
Surface: The inner surface is brushed, the outer surface is painted (white)
Appendix
Doors: three doors, button-pressed
Pressure gauge: analog display
Cabin Tray: 304 Stainless Steel
Control
Manual valve manual operation
Function
Connect two glove boxes, the sample can be transferred from left to right or from the middle to both sides
(5) Gas purification circulation system
Purification Column
Function: airtight, dewatering, deoxidizing
Container material: 304 stainless steel
Purification material: copper catalyst: 5kg, molecular sieve: 5kg
Purification capacity: oxygen removal: 60L, water removal: 2Kg
Water oxygen index: less than 0.1ppm
Circulatory System
Working gas: nitrogen, argon
Circulation capacity: integrated fan flow rate of 90m³/h, with frequency conversion installed
Regeneration
Operation: PLC automatically controls the regeneration process
Regeneration gas: working gas and hydrogen mixed gas, (hydrogen 5-10%)
Vacuum Pump
Specifications: 12m³/h, rotary vane pump, with oil mist filter, gas vibration control
Valve
Main valve: DN 40 KF, electric angle valve
Control valve: solenoid integrated valve (stainless steel integrated valve seat, single column is integrated for six valves)
(6) Control system
Function
including self-diagnosis, self-starting after power failure, with pressure control and self-adaptive functions; automatic
control, cycle control, password protection; unit control adopts Siemens PLC touch screen.
Pressure control
control the pressure of the box and transition cabin, the working pressure of the box can be freely set within +/- 15mbar, and
the system will automatically protect when it exceeds +/- 16mbar
Foot pedal
control the pressure of the box, easy to operate boost and pressure
(7) Display system
Siemens PLC touch screen is used to display the running status, box pressure, system records, etc.
(8) Control of Vacuum System
Vacuum pump, which can be started manually or through PLC, with a flow rate of 12m³/h, which can evacuate the transition chamber
and keep the pressure balance of the box body. The ultimate vacuum degree of the vacuum pump is ≤2x10-1pa
(9)Glove box accessories
Water Analyzer
Measuring range: 0~1000ppm
Accuracy: 0.1ppm
Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen (PPM), and the
alarm value can be set
Using alumina ceramic thin film probe, ultra-high sensitivity, ultra-wide detection range, fast response.
Oxygen Analyzer
Measuring range: 0~1000ppm
Accuracy: 0.1ppm
Display: The output of the analyzer is connected to the PLC, the detection value is displayed on the touch screen (PPM), and the
alarm value can be set
Using electrochemical cells, ultra-high sensitivity, ultra-wide detection range, fast response
Organic Solvent Adsorber
Size: 238mm in diameter, 407mm in height, material: 304 stainless steel with a thickness of 3mm, filled with 10kg of
high-efficiency active adsorption material, connected to the main circulation pipeline, the circulating gas can first pass through
the adsorber, and mainly absorb the volatilized organic gas. With a bypass system, manual valve control can choose to open or
close the solvent adsorption column, and the adsorption material can be replaced quickly and easily. After replacing the activated
carbon, the adsorption column can be evacuated to remove the air and avoid polluting the high-purity atmosphere in the box.
Ultra Clean Filtration System
The top of the box is equipped with a dust removal system. After the gas passes through the dust removal fan and the
high-efficiency dust removal filter element, a laminar flow from top to bottom can be generated, and the gas in the box is sent
back to the dust removal system from the bottom through the circulation pipeline.
Cleanliness: Class 10 (according to US FED standard 209E), ISO4 (according to international standard ISO14644-1)
Filtration system: high efficiency filter H13 grade to ultra high efficiency filter U15 grade
Gas flow rate: can be controlled at 0.2-0.45m/s
Control mode: fan control system with adjustable air volume.
Equipped with differential pressure gauge: measure the pressure difference before and after the dust filter. When the pressure
difference is greater than a certain value, the dust filter needs to be replaced.
Temperature Control System
Integrated into ultra-clean filtration system
Adopt high-efficiency rotary compressor, high heat transfer coefficient heat exchanger, high impedance fan
The compressor is a split floor type to reduce vibration
Function: The temperature in the glove box can be adjusted and set (working temperature 15-36℃);
Display accuracy: 1℃
Rated cooling capacity: 1050W;
Cooling power: 640W






Related Products






Company Profile




FAQ


Q1: How to order?
A: Please send us your purchase order by email or call us sales, or we can make the pro forma invoice under your request. We need to know the following information for your order before sending your PI.
1)Product information-quantity, specification (size, material, Technology if needed and packing requirements etc.
2) Delivery time required.
3)Shipping information company name, street address, phone number, destination sea port.
4) Forwarder's contact details if there is any in china.
Q2: How to control quality?
A. All the raw materials by lOC (Incoming Ouality Control) before launch whole process into the process after the screening.
B. Process each link in the process of IPOC ( lnput Process Ouality Control ) patrol inspection
C.After finished by QC full inspection before packing into the next process packing.
D.OQC before shipment for each slipper to do full inspection.
Q3: How can l install and operate the machine by myself?
A: Our system R&D based on integrated development view. when you get the machine, just need to connect it with the electrical power, then machine can be working. because the English software were installed in this machine. What’s you need to do is only learning the software usage, and the complete English user manual will be coning to you with the machine.
Q4: How to get technical support after purchasing?
A: Our factory providing online technical support in English, you can easy catch us online by SKYPE, WECHAT, WAHTSAPP or Email. if you need any remote assistant support. then we will support you though TeamViewer software.
Q5: What certificates do you have?
A. Since Europe and America are our main markets. all of our products are with CE /FCC compliant For some models, the certificates are already available. For other models, we will need your assistance to apply the certificates.
Q6: What's the warranty for the items?
A: We are very confident in our products, and we pack them very well, so usually you will receive your order in good condition.any quality issue, we will deal with it immediately Warranty for equipment is a year (12 months) lf the equipment parts are damaged due to nonhuman factors within one year. we will provide replacement parts free of charge.