Share on (1600141019314):
a. Applicable to 17 series 40AH and below lithium manganese oxide/lithium cobaltate/lithium ion/lithium polymer/ternary battery pack;
b. Perfect overcharge protection, over-discharge protection, over-current protection, short-circuit protection and disconnection protection;
c. The external protection adopts aluminum heat sink, which is shockproof, drop-proof, anti-impact and increase heat dissipation and increase the strength;
d. The main control IC adopts a highly integrated dedicated battery protection IC with reliable and stable protection functions, low self-loss and ESD protection.
NO | Test items | Min | typical | Max | unit | |||
1 | Charging voltage | 71.06 | 71.4 | 72 | V | |||
2 | Charge MOS tube withstand voltage value | 100(DC) | V | |||||
3 | Discharge MOS tube withstand voltage value | 100(DC) | V | |||||
4 | recharging current | 40 | 43 | A | ||||
5 | Continuous discharge current | 40 | 43 | A | ||||
6 | Discharge overcurrent protection current (100A electronic load) | 85 | 95 | 105 | A | |||
7 | Discharge Overcurrent Protection Delay (Nebula Protection Board Tester) | 300 | 470 | 600 | mS | |||
8 | Single consumable current (3.30V) | 15 | 23 | 33 | uA | |||
9 | Single section overcharge detection voltage | 4.21 | 4.25 | 4.29 | V | |||
10 | Single section overcharge recovery voltage | 4.05 | 4.15 | 4.2 | V | |||
11 | Single section overcharge detection delay | 0.5 | 1 | 2 | S | |||
12 | Single section over discharge detection voltage | 2.67 | 2.75 | 2.83 | V | |||
13 | Single section over discharge recovery voltage | 2.9 | 3 | 3.1 | V | |||
14 | Single section over discharge detection delay | 0.5 | 1 | 2 | S | |||
15 | Short-circuit/over current protection recovery conditions | Short-circuit/overcurrent protection removes load automatically after recovery | ||||||
16 | Overcharge(overdischarge)recovery conditions | Discharge short-circuit/discharge over-current protection removes load automatically after recovery | ||||||
17 | Short circuit protection delay | 500 | 1000 | 1800 | uS | |||
18 | Protection circuit internal resistance | 8 | 15 | mΩ | ||||
19 | Maximum temperature rise of normal current | 45 | 60 | ºC | ||||
20 | Discharge MOS protection temperature | 65 | 70 | 75 | ºC | |||
21 | temperature range of Operating | -20 | 25 | 45 | ºC | |||
22 | temperature range of Save environment | 20 | 25 | 30 | ºC | |||
23 | humidity range of Save environment | ≤40% | ||||||