Share on (1600196893114):
Model | Sun Invm HF - Pro 3KW | Sun Invm HF - Pro 5KW | ||
Rated power | 3KVA/3KW | 5KVA/5KW | ||
PV Input(DC) | ||||
Max. PV array power | 4000W | |||
Nominal PV voltage | 240VDC | |||
PV array MPPT voltage range | 120-450VDC | |||
Max. PV array open circuit voltage | 500VDC | |||
Max. charging current(AC+solar) | 80Amp | |||
AC Input(AC) | ||||
Nominal input voltage | 230VAC | |||
Low loss voltage | 170VAC+7V(UPS), 90VAC+7V(applicance) | |||
Low loss return voltage | 180VAC+7V(UPS), 100VAC+7V(applicance) | |||
High loss voltage | 280VAC+7V | |||
High loss return voltage | 270VAC+7V | |||
Max. Ac input voltage | 300VAC | |||
Nominal input frequency | 50/60Hz(auto detection | |||
Transfer time | 10ms typical (UPS), 20ms typical (applicances) | |||
Battery mode output(AC) | ||||
Nominal output power | 3KVA/3KW | 5KVA/5KW | ||
Surge Power | 6000VA | 10000VA | ||
Nominal output voltage | 230VAC±5% | |||
Output waveform | Pure sine wave | |||
Efficiency(DC to AC / Peak) | 93% | |||
Utility Charger | ||||
Nominal DC voltage | 24VDC | 48VDC | ||
Maximun Charging current | 60Amp | |||
Bulk charging voltage | 29.2VDC | 58.4VDC | ||
Floating charging voltage | 27VDC | 54VDC | ||
Overcharge protection | 33VDC | 63VDC | ||
General | ||||
Dimension | 100X300X440mm | |||
Net weight | 9kg | 10kg | ||
Commuynication port | RS-232/USB | |||
Humidity | 5-95% RH(Non condensing) | |||
Working tempreture | -10 - 55℃ | |||
Altitude | 0-1000M |