Product Description


Full inverter swimming pool heat pump



1. Full DC inverter technology
Macon DC inverter swimming pool heat pump use full inverter technology, DC inverter compressor and inverter fan motor, the working
frequency will change according to ambient temperature and water temperature, so the unit works at best performance.
2. Low noise design
The compressor is equip with low noise muffler button, and we choose low noise fan motor. All the copper pipe and the cabinet will
design for low noise.
3. High COP
Macon DC inverter pool heat pump have high COP to 18
4. Wifi control
Macon swimming pool heat pump have wifi control, so you can control the pool heat pump anywhere.
5. Wide working temperature range
Inverter swimming pool heat pump can work at -20°C~43°C
6. Eco-friendly refrigerant
With R32 refrigerant in Europe, it is no pollution to environment.
7. Multi-protection
Macon pool heater with water flow switch prection, compressor protection, anti-freezing protection, which makes your unit works safety.


Swimming Pool
Heat Pump Stars series
Compressor type
Outlet water temperature range
Operating ambient temperature range
Refrigerant type
Comfort Stars
Constant Speed
cooling:7°C~25°C
heating:25°C~45°C
-7°C~43°C
R32 OR R410A
Warm Stars
EVI Constant Speed
cooling:7°C~25°C
heating:25°C~45°C
-25°C~43°C
R32 OR R410A
Wisdom Stars
Full DC Variable Speed
cooling:7°C~25°C
heating:25°C~45°C
-25°C~53°C
R32 OR R410A
Strong Heating Stars
EVI Full DC Variable Speed
cooling:7°C~25°C
heating:25°C~45°C
-35°C~53°C
R32 OR R410A


Specification


Model(Plastic Shell)

MALCRW
010ZAB1-R32
015ZAB1-R32
020ZAB1-R32
025ZAB1-R32
Power Supply
V/PH/Hz
220/1/50
220/1/50
220/1/50
220/1/50
Heating Capacity
Range
kW
1.1~4.3
1.3~5.2
2.2~8.6
2.75~11
BTU/h
3753~14672
4436~11742
7336~29343
9383~37532
COP Range
W/W
3.6~13
3.6~13
3.6~13
3.6~13
Heating Capacity①
kW
4.3
5.2
8.6
11.0
BTU/h
14672
17742
29343
37532
COP① A:30/W:28
W/W
6.2
6.2
6.2
6.2
Input Power①
kW
0.69
0.84
1.39
1.77
Input Current①
A
3.2
3.8
6.3
8.1
Heating Capacity②
kW
4.3
5.2
8.6
11.0
BTU/h
14672
17742
29343
37532
COP② A:24/W:28
W/W
5.60
5.60
5.60
5.60
Input Power②
kW
0.77
0.93
1.54
1.96
Input Current②
A
3.5
4.2
7.0
8.9
Heating Capacity③
kW
4.3
5.2
8.6
11.0
BTU/h
14672
17742
29343
37532
COP③ A:15/W:28
W/W
4.8
4.8
4.8
4.8
Input Power③
kW
0.90
1.08
1.79
2.29
Input Current③
A
4.1
4.9
8.1
10.4
Heating Capacity④
kW
4.0
4.8
8.0
10.0
BTU/h
13648
16378
27296
34120
COP④ A:7/W:28
W/W
4.2
4.2
4.2
4.2
Input Power④
kW
0.95
1.14
1.90
2.38
Input Current④
A
4.3
5.2
8.7
10.8
Heating Capacity⑤
kW
3.6
4.3
7.2
9.2
BTU/h
12283
14672
24566
31390
COP⑤ A:0/W:28
W/W
3.72
3.72
3.72
3.72
Input Power⑤
kW
0.97
1.16
1.94
2.47
Input Current⑤
A
4.4
5.3
8.8
11.2
Heating Capacity⑥
kW
3.0
3.6
6.0
7.5
BTU/h
10236
12283
20472
25590
COP⑥ A:-7/W:28
W/W
3.16
3.16
3.16
3.16
Input Power⑥
kW
0.95
1.14
1.90
2.37
Input Current⑥
A
4.3
5.2
8.6
10.8
Compressor
Rotary
Rotary
Rotary
TWIN Rotary
Compressor Qty
1
1
1
1
Fan Qty
1
1
1
1
Noise
dB(A)
48
48
48
52
Water Out let/Water In let
inch
1–1/2"
1–1/2"
1–1/2"
1–1/2"
Water Flow Volume
m3/h
3.68
3.68
3.68
5.44
Water Pressure Drop
kpa
12
12
12
15
Fan Direction
horizontal
horizontal
horizontal
horizontal
Refrigerant Type
R32
R32
R32
R32
Unit Net Dimensions ( L/M/H )
mm
900/340/665
900/340/665
900/340/665
1040/410/765
Unit Shipping Dimensions ( L/M/H )
mm
1000/375/695
1000/375/695
1000/375/695
1088/495/685
Net Weight
kg
50
55
60
75
Shipping Weight
kg
54
59
64
79


Model(Plastic Shell)

MALCRW
040ZAB1-R32
050ZAB1-R32
060ZAB1-R32
060ZASB1-R32
Power Supply
V/PH/Hz
220/1/50
220/1/50
220/1/50
380/3/50
Heating Capacity
Range
kW
4.38~17.5
5.25~21
6.45~25.8
5.25~21
BTU/h
14928~59710
17913~71652
22007~88030
17913~71652
COP Range
W/W
3.6~13
3.6~13
3.6~13
3.6~13
Heating Capacity①
kW
17.5
21.0
25.8
21.0
BTU/h
59710
71652
88030
71652
COP① A:30/W:28
W/W
6.2
6.2
6.2
6.2
Input Power①
kW
2.82
3.39
4.16
3.39
Input Current①
A
12.8
15.4
18.9
5.2
Heating Capacity②
kW
17.5
21.0
25.8
21.0
BTU/h
59710
71652
88030
71652
COP② A:24/W:28
W/W
5.60
5.60
5.60
5.60
Input Power②
kW
3.13
3.75
4.61
3.75
Input Current②
A
14.2
17.0
20.9
5.7
Heating Capacity③
kW
17.5
21.0
25.8
21.0
BTU/h
59710
71652
88030
71652
COP③ A:15/W:28
W/W
4.8
4.8
4.8
4.8
Input Power③
kW
3.65
4.38
5.38
4.38
Input Current③
A
16.6
19.9
24.4
6.7
Heating Capacity④
kW
16.7
19.5
23.5
19.5
BTU/h
56980
66534
80182
66534
COP④ A:7/W:28
W/W
4.2
4.2
4.2
4.2
Input Power④
kW
3.98
4.64
5.60
4.64
Input Current④
A
18.1
21.1
25.4
7.1
Heating Capacity⑤
kW
14.4
17.5
21.0
17.5
BTU/h
49133
59710
71652
59710
COP⑤ A:0/W:28
W/W
3.72
3.72
3.72
3.72
Input Power⑤
kW
3.87
4.70
5.65
4.70
Input Current⑤
A
17.6
21.4
25.7
7.2
Heating Capacity⑥
kW
12.0
15.0
18.0
15.0
BTU/h
40944
51180
61416
51180
COP⑥ A:-7/W:28
W/W
3.16
3.16
3.16
3.16
Input Power⑥
kW
3.80
4.75
5.70
4.75
Input Current⑥
A
17.3
21.6
25.9
7.2
Compressor
TWIN Rotary
TWIN Rotary
TWIN Rotary
TWIN Rotary
Compressor Qty
1
1
1
1
Fan Qty
1
1
1
1
Noise
dB(A)
54
54
54
54
Water Out let/Water In let
inch
1–1/2"
1–1/2"
1–1/2"
1–1/2"
Water Flow Volume
m3/h
7.38
9.21
9.21
9.21
Water Pressure Drop
kpa
15
16
16
16
Fan Direction
horizontal
horizontal
horizontal
horizontal
Refrigerant Type
R32
R32
R32
R32
Unit Net Dimensions ( L/M/H )
mm
1180/450/865
1180/450/865
1180/450/865
1180/450/865
Unit Shipping Dimensions ( L/M/H )
mm
1280/505/895
1280/505/895
1280/505/895
1280/505/895
Net Weight
kg
103
110
125
110
Shipping Weight
kg
110
117
132
117










Company Profile










Certifications








FAQ


Q: Do you provide OEM or ODM service?
A: Yes. We can produce Macon standard products under customer's brand, or modify the products to satisfy customer's personalized requirements, or work together with customer to design and produce a totally new products.

Q: What support do you offer to Customers?
A: We can provide product certification requirements for local markets, product catalogs, Installation and user manuals and co-exhibit with the customers in leading industry exhibitions.

Q: How long can I get the feedback after sending the inquiry?
A: Usually you will get feedback within 30 minutes during the office hours and 12 hours after office hours.

Q: What’s the payment terms?
A: Normally 30% TT in advance and 70% TT before delivery. Other payment terms are negotiable.

Q: How long is the production lead time?
A: Usually the production lead time will be 30 days once order confirmed. Sometimes we have a few stock for quick delivery.


Contact Us


E-mail:sales5@macon.com.cn




0.2155 s.