Share on (1600244018955):





Model | HA-IO014A-CCX350/S | HA-IO040BF-CCX1000/S | HA-IO045A-CCX1050/S | ||||
Voltage Range | AC100-250V | ||||||
Limited Voltage | 265VAC | ||||||
Power Factor | >0.9 | ||||||
T.H.D | <10% | ||||||
Efficiency | 83% | 85% | 87% | ||||
Output | Rate Power | 14W | 40W | 45W | |||
Rate Current | 350mA | 1000mA | 1050mA | ||||
DC Voltage | DC9-42V | DC9-42V | DC9-42V | ||||
Current Accuracy | ±3% | ||||||
Power-on Time | <0.5s | ||||||
Protection | Short Circuit | constant voltage mode, recover automatically after fault condition is removed | |||||
Over Loading | ≤120% constant voltage limiting, recover automatically after fault condition is removed | ||||||
Over Temperature | 100℃±10℃ Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
Others | Ta | 45℃ | |||||
Tc | 80℃ | ||||||
IP rating | IP20 | ||||||
Life span | 50000hours | ||||||
Warranty | 5years | ||||||
Notes | 1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation . 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | ||||||