One Touch Blue Blood Glucose Diabetic Test Strips

Share on (1600288040920):


Price:$2.10 - $2.50

Quantity:


Product Overview

Description



Product Description



blood glucose test strips

Technical specifications

Product: Test Strips for Blood Test: 50/100-unit box.

Test method Glucose Oxidase biosensor

Test result range 10 ~ 600 mg / dL (0.6 ~ 33.3 mmol / L)

Test time required 5 sec.

Blood amount required 0.8μℓ

Blood reference type Plasma reference

Measuring unit mg / dL, mmol / L

 packaging:a bottle(25T vials) or (50T vials)

Authentication:ISO/GXFDA


OEM/ODM



Storage and Handling
* Store the test strip package in a cool,dry place not above30℃(86℉).Keep away from direct sunlight and heat.Do not refrigerate.
* Store your test strips in their original vial only,do not transfer them to a new vial or any other container.
* After removing a test strip from the vial,immediately replace the vial cap and close it tightly.
* Use each test strip immediately after removing it from the vial.
* Write the discard date on the vial label when you first open it.Discard remaining strips 3 months after first opening the vial.
* Do not use test strips beyond the expiration date printed on tha package since they may cause inaccurate results.

WARNING:Keep the test strip vial away from children;the cap is a choking hazard.Also,the cap or vial may contain drying agents that are harmful if inhaled or swallowed and may cause skin or eye irritation.
Precaution to Obtain Accurate Results
* Code the Blood Glucose Meter to match the code number printed on the test strip vial.
* Never make significant changes to your diabetes control program or ignore physical symptoms without speaking with your healthcare professional.


Quality Control:Checking the System
Do a Control Solution Test:
* When you begin using a new vial of test strips
* At least once a week
* Whenever you suspect that the meter or test strips are not working properly
* If you drop the meter

When control solution is applied to the top edge of the test strip,you should get results within the espected range printed on the
test strip vial.If control solution test results fall outside range,repeat the test.Results that fall outside the range may be
caused by:
* Error in performing the test
* Failure to shake the control vial well enough(must shake vigorously)
* Expired or contaminated control solution
* Improper coding of the meter
* Test strip deterioration
* Meter malfunction
* Control solution that is too warm or too cool
* Failure to discard the firstg drop of control solution



LIMITATIONS
Test Strips give accurate results when the following limitations are observed:
* The test strips should not be used for the testing of newborns.
* The test strip are for single use only.Do not reuse.
* The test strips are specific to D-glucose and do not resct to other sugars wich may be present in blood.
* Use only fresh capillay whole blood.Do not use serum or plasma.

Healthcare professionals-please additional limitations:
* Fresh capillary blood may be collected into heparin-containing test tubes if the blood is used within 10 minutes.Do not use other anticoagulants or preservaties.
* Interferences:Acetaminophen,salicylates,uric,ascorbic acid (vitamin C)and other reducing substances(when occurring in normal blood or normal therapeutic concentrations)do not significantly affect results.However,abnormally high concentrations in blood may cause inaccurately high rsults.
* Patients undergoing oxygen therapy may yield falsely lower results.
* Test results may be falsely low if the patient is severely dehydrated,in shock,or in a hyperosmolar state (with or without
ketosis).Critically ill patients should not be tested by blood glucose meters.

·Lipemic samples:Cholesterol leves up to 600mg/dL(15.5mmol/L)and triglycerides up to 400mg/dL(4.5mmol/L)do not affect the results.









Payment


 We support a lot payment terms

 T/T,L/C,Western Union,Paypal,Money Gram etc.We also welcome RMB payment.



Shipping


1)samples or small order:we can deliver goods within 1 working day by below listed couries etc.

2)big order like 3,000-10,000 sets,we can deliver goods by air or by sea within 3-5working days.


3) *More than 10000 bottles, negotiate



Related product


Specification: Blood Glucose Test Strips

Sample:Fresh capillary whole blood

Sample volume: Minimum 2 μL

Unit: mmol/L (mg/dL optional)

Test time: 5 seconds

Measuring range:20-600mg/dL(1.1-33.3mmol/L)



Sample:Fresh capillary whole blood

Sample volume: Minimum 1 μL

Measuring range: 1.1-33.3mmol/L (20-600mg/dL)

Test time: 5 seconds

Memory: 200 test results






About Us


Company profile

Guilin Renke Medical Technology Development Co., Ltd was found in 2009. It is a high-tech enterprise specializing in researching, designing, manufacturing and selling medical supplies, especially Blood Glucose Meter and Blood Glucose Test Strips. 

Guilin Renke Medical Technology Development Co., Ltd has modern workshop and facilities with GMP standard. With years' work and investment, professional research team has been built up successfully. 

The principle of Guilin Renke Medical Technology Development Co., Ltd is "Quality is top priority". Test strips its manufactured have been well received among customers home and abroad by its accuracy and stability. They can also be used with One-Touch Ultra brand. Goods can also be produced according to customers' specific requirements. Renke believes that customers are the most important.







Contact US


Carmen  (Foreign Trade Manager)

Tel:86-15820765870

Whatsapp:+8615820765870

Website: //renke11.chemdrug.com/

Address:No.1 Qunzhong Road, Diecai District, Guilin, Guangxi, R.P.China 

We are always being ready for help!