LP Series:Low Pressure RO Element


 


Brief Introduction


LP series(low pressure) aromatic polyamide  RO element is developed by VONTRON for treatment of brackish water .It has the characteristics of low-pressure in operation, high permeate flow and excellent rejection performance in removing of solvable salts, TOC ,SiO2,etc.It is especially suitable for the preparation of high purity water in electronics and power industry.


 


Scope of Application


LP series is normally suitable for treatment of brackish water,surface water, underground water and municipal water with TDS is less than 10000 ppm.It is mainly used for producing various scales of bottle water, drinking water,industrial used pure water,high purity water, boiler replenishment water, also for Waste water recycling ,material concentration,purification and refining purposes.


1.png


 


 


 


 


Specifications and Major Properties










































Model



Active Membrane Area ft²(m²)



Permeate flow GPD (m³/d)



Stable Rejecion Rate %



LP440



440 (40.9)



12500(47.3)



99.7



LP22-8040



400(37.2)



10500(39.7)



99.5



LP100



100(9.3)



2500(9.4)



99.7



LP11-4040



90(8.4)



3000(11.4)



99.3



LP21-4040



90(8.4)



2400(9.1)



99.5



 


Testing Conditions


 


Testing Pressure…………………………………225 psi (1.55Mpa)


Temperature of Testing Solution  ………………25 °C


Concentration of Testing Solution (NaCl)……  2000 mg/l


PH Value of Testing Solution……………………7.5


Recovery Rate of Single Membrane Element…15%


 


Operation limits and Conditions


 


Max. Working Pressure…………………………………… 600psi(4.14Mpa)


Max. Volume of Feed water………………………………8040-75gpm (17m³/h) 4040-16gpm(3.6m³/h) 


Max. Temperature of Feed water………………………… 45°C


Max. Feed water SDI15……………………………………  5


pH Range of Feedwater during Continuous Operation… 2~11


pH Range of Feedwater during Chemical Cleaning………1~13


Residual chlorine Concentration of Feed water………… <0.1mg/L


Max. Pressure Drop of Single Membrane Element………… 15psi(0.1Mpa)