Share on (1600306257977):






Karl Fischer moisture titrator (volume method) | ||||
Model | JH-V3 | JH-V5 | ||
Measuring range of moisture content | 0.001~100% | 0.001%-100 (10ppm-100%) | ||
Titration control accuracy | 1 uL | 0.2uL | ||
Titration function | PID automatic control titration speed, drift automatic update automatic deduction; Automatic hold end | PID automatic control titration speed, drift automatic update automatic deduction; Automatic hold end | ||
Accessibility | Automatic cleaning function, equipment verification function, waste liquid bottle full warning function, automatic data calculation, result statistics function | Automatic cleaning function, equipment verification function, waste liquid bottle full warning function, automatic data calculation, result statistics function | ||
Delay setting | Delay titration and terminal delay can be set according to the need to deal with insoluble samples | Delay titration and terminal delay can be set according to the need to deal with insoluble samples | ||
Titration repeatability (RSD) | RSD≤0.5% ; (2ml reagent) | RSD≥99.7% ; (2ml reagent) | ||
measure time | 3 minutes on average | 3 minutes on average | ||
data processing | Automatic calculation analysis results, showing consumption test dose, water quality, percentage content, PPM, etc | Automatic calculation analysis results, showing consumption test dose, water quality, percentage content, PPM, etc | ||
data storage | There are 5 method files | 12 groups | ||
The measurement results | 20 groups | 20 groups | ||
Built-in printer | YES | YES | ||
Valve and pipe material | Three - way two - way solenoid drive control valve, anti-corrosion material pipeline and sealing joint | Three - way two - way solenoid drive control valve, anti-corrosion material pipeline and sealing joint | ||
External electrode | Double platinum electrode | Double platinum electrode | ||
Operation interface | LCD screen display, navigation operation menu | LCD screen display, navigation operation menu | ||
Use environment humidity | ≤80% | ≤80% | ||
power supply | 95~260V / 50Hz | 110~220V (AC) / 50-60Hz | ||
Size | 580*460*360mm | 580*460*360mm | ||
Weight | 9.6kg | 9.6kg | ||
Karl Fischer Moisture Titrator (Coulometric Method) | ||||
Model | JH-C3 | JH-C5 | ||
Measuring range | 3ug~1000mg (H2O) | 3ug~199mg (H2O),1ppm~100% | ||
Reading unit | ug water | ug water | ||
Detection accuracy | 0.1 ug (H2O) | 0.1 ug (H2O) | ||
Accuracy | >99.7% (1000 ug Pure water ) | >99.7% (1000 ug Pure water ) | ||
Electrolysis current range | 0-400mA | 0-400mA | ||
temperature range | - | 0-299℃ | ||
End delay | Customizable | Customizable | ||
Electrolysis speed | According to the electrolysis capacity of the reagent, select 6 gears, automatic control | According to the electrolysis capacity of the reagent, select 6 gears, automatic control | ||
Drift handling | Intelligent tracking, automatic processing | Intelligent tracking, automatic processing | ||
Calculation formula | 6 formulas to adapt to different calculation needs | 6 formulas to adapt to different calculation needs | ||
Operation interface | Touch color screen | Touch color screen | ||
Data storage | 100 group | 200 group | ||
Calibration function | YES | YES | ||
Printer | Pr-1 dedicated data printer | Pr-1 dedicated data printer | ||
Power supply | 220V / 50Hz | 220V / 50Hz | ||
Power | 35W | 35W | ||
Ambient temperature | 5-40℃ | 5-40℃ | ||
Environment humidity | 20~80% | 20~80% | ||
Dimensions | 320*280*160mm | 320*280*160mm | ||
Net weight | 5.0kg | 5.0kg | ||







New products from manufacturers at wholesale prices