Custom hvac system double skin air handling system in pharmaceutical industry (1600349407336)

Share on:


Price:$2,500.00 - $2,890.00
Price in USD:Details

Quantity:


Product Overview

Description



Company Profile






Product Description


Unit Function Section
The combined air conditioning unit of the clean operating room can be designed with different air treatment functional sections: fresh return air mixing section, primary filter section, surface cold dehumidification section, heating section, humidification section, secondary return air mixing section, fan section, and current equalization section , Medium-efficiency filter section, sub-high-efficiency filter section, sterilization section, air supply section, host side, etc., through the unit function section to perform one or more treatments on the air to meet the required technical requirements for working conditions and effects




Function section name
1
Mixed section
7
Current sharing section
2
Primary-efficiency filter section
8
Medium-efficiency filter section
3
Coil dehumidification section
9
Sub-high efficiency filter section
4
Heater section
10
Sterilization section
5
Humidification section
11
Wind out section
6
Fan section
12
Host segment


Features
1. High-strength structure: adopts high-strength cooling bridge aluminum alloy profile frame, beautiful appearance and high strength;
2. No deformation: The inner and outer panels and the insulation layer are foamed at one time, and the foaming density is not less than 48kg/m3, which can ensure that the unit does not deform under the pressure difference between the inside and outside of 2500Pa;
3. Anti-cold bridge: high-strength anti-cold bridge aluminum alloy structure, PA66 heat insulation material, completely solve the frame condensation problem;
4. Low air leakage rate: regardless of positive pressure or negative pressure, the air leakage rate is less than 1% under the
pressure difference of 1000 Pa between the inside and outside of the machine;
5. Personalized design: improve non-standard customized designs such as annual refrigeration, low-temperature heating,
low-temperature air supply, and compressor frequency conversion, and tailor-made technical solutions for clean projects.


Specification


Unit quick selection table(cooling capacity of coil section under fresh air condition)


Model
Nominal air volume m³/h
4 rows
6 rows
8 rows
Cooling capacity
Water volume
Cooling capacity
Water volume
Cooling capacity
Water volume
kW
m³/h
kW
m³/h
kW
m³/h
SLZK015W
1500
18.9
3.3
23.5
4.04
28.1
4.83
SLZK018W
1800
23.5
4.0
29.4
5.06
35.1
6.04
SLZK022W
2200
28.3
4.9
35.3
6.07
42.2
7.25
SLZK032W
3200
41.3
7.1
51.4
8.84
61.5
10.57
SLZK038W
3800
49.5
8.5
61.7
10.61
73.8
12.69
SLZK050W
5000
66.2
11.4
82.3
14.15
98.4
16.92
SLZK063W
6300
82.3
14.2
102.8
17.68
122.9
21.15
SLZK072W
7200
94.5
16.3
117.5
20.21
140.5
24.17
SLZK095W
9500
122.9
21.1
152.8
26.27
182.7
31.42
SLZK120W
12000
153.2
26.4
190.9
32.84
228.3
39.27
SLZK150W
15000
195.6
33.6
248.2
42.69
296.8
51.05
SLZK180W
18000
245.6
42.2
305.5
52.55
365.3
62.83
SLZK230W
23000
302.1
52.0
376.0
64.67
449.6
77.33
SLZK270W
27000
358.7
61.7
446.5
76.80
533.9
91.83
SLZK320W
32000
426.1
73.3
530.2
91.20
634.0
109.05
SLZK370W
37000
492.8
84.8
613.9
105.60
734.1
126.27
SLZK430W
43000
560.8
96.5
697.7
120.00
834.2
143.49
SLZK500W
50000
648.9
111.6
807.8
138.94
965.9
166.14
SLZK550W
55000
727.6
125.1
904.8
155.62
1081.9
186.08
SLZK630W
63000
826.4
142.1
1028.1
176.84
1229.4
211.45
SLZK700W
70000
924.8
159.1
1151.5
198.06
1376.9
236.83
SLZK760W
76000
1005.4
172.9
1248.4
214.73
1492.8
256.76
SLZK850W
85000
1124.3
193.4
1398.3
240.50
1672.0
287.58
SLZK930W
93000
1200.6
206.5
1514.6
260.51
1812.4
311.73
SLZK1000W
100000
1320.6
227.1
1671.4
287.48
2010.3
345.77
SLZK1100W
110000
1450.7
249.5
1825.7
314.02
2186.5
376.08


Note:
1. The inlet temperature of chilled water is 7℃, and the outlet temperature is 12℃;
2. Fresh air conditions: inlet air dry bulb temperature 35℃, wet bulb temperature 28℃;
3. The above parameters are for reference only. If the working conditions and coil circuit arrangement are changed, the parameters will change.


Unit quick selection table(parameter table of DX outdoor unit of clean room air conditioning unit)


Model
SRF8W
SRF18W
SRF24W
SRF30W
SRF36W
SRF45W
SRF51W
Cooling capacity
kW
7.5
17.6
24
30.6
36.3
44.7
51.2
Heating capacity
kW
8.1
19.1
26.1
33.5
39.7
48.9
56.3
Input power
kW
2.7
5.4
7.3
9.3
11
13.5
15.6
Supply power
3Ph 380V 50Hz
Energy control
0,100%
0,100%
0,100%
0,100%
0,100%
0,100%
0,30%,70%,100%
Refrigerant
R410A
Compressor
Type
Scroll compressor
Qty
1
1
1
1
1
1
2
Fan
Type
Axial fan
Air volume
m³/h
5500
8000
9000
12000
14000
17000
20000
Power
kW
0.20
0.37
0.55
0.75
0.75
1.10
1.50
Qty
1
1
1
1
1
1
1
Condenser
Copper tube and aluminum fin
Connecting pipe of indoor and outdoor unit
Liquid pipe
Type
φ9.52x1
φ12.7x1
φ16x1
φ16x1
φ16x1
φ19x1
φ12.7x1+φ16x1
Qty
1
1
1
1
1
1
2
Gas pipe
Type
φ16x1.0
φ19x1.0
φ28x1.2
φ28x1.2
φ28x1.2
φ35x1.5
φ19x1+φ28x1.2
Qty
1
1
1
1
1
1
2
Dimension
L
mm
930
800
930
960
960
1060
1350
W
mm
370
860
820
1020
1020
1090
1060
H
mm
700
1115
1115
1115
1115
1240
1240
Weight
kg
65
124
154
175
180
232
254


Note:
1. The above models are for reference only, and different working conditions will lead to different parameters;
2. Compressor frequency conversion series can be customized according to non-standard;
Note:
1. Cooling capacity calibration working condition: ambient temperature 35℃, inlet air temperature 27/19℃;
2. Heating capacity calibration working conditions: ambient dry and wet bulb temperature 7/6℃, inlet air temperature 20℃;
3. The above parameters are for reference only. If the working conditions are changed, the parameters will be changed.


Application


The functions of the combined air conditioning unit of the clean operating room are flexibly combined according to the working conditions and technical design requirements, and can meet the needs of air purification and temperature and humidity adjustment systems in all walks of life. This product is widely used in medical treatment, medicine, electronic instruments, precision machinery, and products. The air-conditioning purification projects of enterprises such as, light industry and chemical industry are also suitable for the comfortable centralized air-conditioning projects of large and medium-sized public buildings such as scientific research buildings, hospitals, laboratories, training rooms, exhibition halls, shopping malls, and theaters.


Product schematic diagram


General comfortable occasion air handling unit
Configuration of basic function, early efficient filter and hot coil in air handling units (choose wet membrane humidification), it has the simple and highly controllable size characteristics of the function.
Suitable for general building room comfort air conditioning process.




Air handling units for operating room and high clean requirement occasion
In addition to the basic function of configuration, with primary efficiency filter or medium efficiency filter, it equipped with
electric heating and humidification section. Considering particularity of medical situations, AHU adopt double cold source system ( chilled water + direct expansion) and efficient unhoused centrifugal fan, provide frequency conversion control, in order to satisfy the high reliability requirements.





Air handling units with heat recovery device
Can configured with wheel heat recovery device, hot and cold air passes through hot wheel, heat and moisture exchange is carried out by the difference of temperature and steam pressure between fresh air and exhaust air, effective recovery of sensible heat and latent heat in exhaust air, achieve the purpose of energy conservation.Honeycomb structure with aluminum foil carrier and high efficient moisture absorbing coating for heat storage core body of heat exchanger, excellent characteristics of heat storage, moisture absorption and heat transfer, efficiency is higher than 75%.




Can configured with plate fin heat recovery device, so that the cold hot air flow directly through the same heat exchanger, in order to achieve the purpose of heat exchange.The heat exchanger adopts ginning aluminum foil, corrugated aluminum foil heat exchanger made of heat conductor, no interme-diate heat medium is required,no power consumption,no loss of temperature difference,temperature efficiency is higher than 75%.