Share on (1600430209137):

Accessories included: | USB charger, power cable, and clips |
Auto-buffer recognition: | Yes |
Backlight: | Yes |
Barometric pressure measurement: | Automatic compensation of DO when using an LDO or LBOD probe |
Cable length: | 1 m |
Calibration intervals/alerts/reminder: | Off, selectable from 2 hours to 7 days |
Certifications: | CE, FCC, ISED, RCM, KC, ETL Verified: US DOE/ NRCan Energy Efficiency, RoHS |
Conductivity calibration: | Demal (1D/ 0.1D/ 0.01D); |
Molar (0.1M/ 0.01M/0.001M); | |
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm); | |
Standard sea water; | |
User defined | |
Conductivity measurement: | Temperature correction:None; Linear; NaCl Non-Linear Natural Water. |
Conductivity measurement range: | Yes |
Custom calibration standards: | Yes |
Data export: | USB connection to PC or USB storage device (limited to the storage device capacity). |
Data storage: | 10,000 data points |
Automatic in Press to Read Mode and Interval Mode. Manual in Continuous Read Mode. | |
Dimensions (H x W x D): | 63 mm x 97 mm x 220 mm |
Display: | Up to 3 parameters at a time, dependent on HQ model |
Display type: | 536x336 Mono-TFT |
DO measurement range: | 0.1 - 20.0 mg/L (ppm), 1 - 200% saturation |
DO resolution: | 0.1 |
Electrode type: | Intellical Standard Laboratory or Rugged Field |
Enclosure waterproof rating: | IP67 (with battery compartment installed) |
Environmental conditions: | relative humidity:90% (non-condensing) |
Environmental conditions: temperature: | 0 - 60 °C |
GLP features: | Date; Time; Sample ID; Operator ID, Calibration |
Inputs: | 2 |
Instrument: | Portable |
ISE direct measurement: | No |
ISE electrode calibration: | No |
Kit?: | Yes |
Languages user interface: | English, Chinese - Simplified, Spanish, French, German, Italian, Japanese, Turkish, Dutch, Portuguese (PT & BR), Korean, Danish, Swedish, Polish, Norwegian, Hungarian, Greek, Finnish, Czech, Romanian, Croatian, Bulgarian, Slovak, Lithuanian, Estonian, Slovenian, Russian |
Lock function: | Continuous / Auto-stabilisation ("press to read") / At Interval |
Measurement method: | Probe specific programmed method settings |
Model: | HQ2200 Multi/2 Channels |
mV measurement at stable reading: | Yes |
mV measurement range: | Yes |
mV resolution: | 0.1 mV |
Operating error messages: | Clear text error messages displayed |
Operating Interface: | Soft Touch Keypad |
ORP electrode calibration: | Predefined ORP standards (including Zobell's solution) |
Parameter: | pH, Conductivity |
pH Buffer Sets: | Colour-coded: 4.01, 7.00, 10.01 pH; |
IUPAC: 1.679, 4.005, 7.000, 10.012, 12.45 | |
DIN: 1.09, 4.65, 9.23 | |
User-defined custom buffer sets | |
pH Electrode calibration: | 1 - 3 Calibration points |
Calibration summary data logged and displayed | |
pH Measurement Range: | 0 - 14 pH |
pH Resolution: | Selectable: |
0.001/0.01/0.1 pH | |
Power supply: | Rechargeable lithium-ion battery 18650 (internal) |
Class II, USB power adapter: 100 - 240 VAC, 50/60 Hz input; 5 VDC at 2 A USB power adapter output (external) | |
Probes included?: | PHC10101, CDC40101 |
Protection class: | IEC Class III (SELV (Separated/Safety Extra-Low Voltage) powered); external |
Region: | EU |
Resolution: | 0.01 mg/L - 0.1 g/L upon measuring range |
Salinity measurement range: | 0 - 42 (ppt) (‰) |
Salinity resolution: | 0.01 (ppt) (‰) |
Sensor A: | PHC10101, CDC40101 |
Sensor B: | CDC40101 |
Sensor C: | None |
Software available: | Claros |
Storage conditions: | -20 - 60 °C, max. 90% relative humidity (non-condensing) |
TDS measurement range: | 0.00 mg/L - 50.0 g/L NaCl |
Temperature compensation: | Automatic Temperature compensation for pH |
Temperature measurement range: | °C or °F |
Temperature resolution: | 0.1 °C |
Type of measurement: | Field Measurements |
Warranty: | 24 months |
Weight: | 541 g (Meter only) |