Item | Description | |
Input Power Supply | Input Voltage | Three-phase 380V/480V/660 AC |
Frequency | 50/60Hz | |
Adaptive Motor | Squirrel-cage three-phase asynchronous motor | |
Starting Times | It is recommended not to exceed 20 times per hour. | |
Control Mode | (1) Operation panel control. (2) Operation panel + external control. (3) External control. (4) External control + COM control. (5) Operation panel + external + COM control. (6) Operation panel + COM control. (7) COM control. (8) No start or stop operation | |
Start Mode | (1) Current-limiting to start. (2) Voltage ramp to start. (3) Torque control + current-limiting to start. (4) Torque control + voltage ramp to start. (5) Current ramp to start. (6) Voltage current-limiting double closed-loop start | |
Stop Mode | (1) Soft stop. (2) Free stop | |
Protective Function | (1) Open loop protection for external instantaneous stop terminals. (2) Over-heat protection for soft starter. (3) Protection for too long starting time. (4) Input open phase protection. (5) Output open phase protection. (6) Unbalanced three-phase protection. (7) starting over current protection. (8) Running overload protection. (9) Under voltage protection for power voltage. (10) Overvoltage protection for power voltage. (11) Protection for fault parameter setting. (12) Load short circuit protection. (13) Auto restart or incorrect wiring protection. (14)Incorrect wiring protection of external control stop terminals. | |
| Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. |
Altitude | Below 1000M. It have to rise the rate power when the altitude is more than 1000M. | |
| Temperature | -20 +45 o C | |
| Humidity | 90%RH without dew condensation. | |
| Vibration | <0.5G | |
| Structure | Protection Class | IP20 |
| Cooling Pattern | Fans cooling. | |
1. Reduce the starting current, reduce power supply peak current, reduce the cost of distribution
equipment.
2. Reduce the abrasion of motor, improve the service Life of Mechanical Equipment.
3. Optional parameters are starting convenient in one soft starter different starting motors.
4. Inspects motor feedback voltage soft starter to realize closed loop control, motor start-up ensure
the success in different conditions and different loads.
5. A Variety of Ways starting: Voltage RAMP starting Way can get the maximum output torque; Current
limiting can realize biggest Limitations of the start soft starting current.
6. Reliable quality Assurance: using computer simulation design; SMT production process; electromagnetic
compatibility excellent performance; high temperature aging, vibration test before delivery of the machine.
7. Perfect and Reliable Protection function: Loss of Voltage, less Voltage, over Voltage Protection;
Overheating, TOO Long starting time;
8. Input Phase Lost, Lost output Phase, Three-Phase imbalance; starting over current,
overload and load Protection Short circuit, etc .
9. Full-field Bus Monitoring Dynamic Control Starter, easy networking.
10. LCD screen can display displaying parameter code, state and error.