Share on (1600467715310):





RF2.4G remote control Dimming | ||||||||||
Model | Rated Power | Output Current | Output Voltage | Efficiency | Power Factor | |||||
HA-RFCH016BF-CC400 | 16W | 400mA | 25-40V | 83 | 0.9 | |||||
HA-RFCH018BF-CC450 | 18W | 450mA | 25-40V | 83 | 0.9 | |||||
HA-RFCH020BF-CC500 | 20W | 500mA | 25-40V | 83 | 0.9 | |||||
HA-RFCH022BF-CC550 | 22W | 550mA | 25-40V | 85 | 0.9 | |||||
HA-RFCH024BF-CC600 | 24W | 600mA | 25-40V | 85 | 0.9 | |||||
HA-RFCH026BF-CC650 | 26W | 650mA | 25-40V | 85 | 0.9 | |||||
HA-RFCH028BF-CC700 | 28W | 700mA | 25-40V | 85 | 0.9 | |||||
HA-RFCH030BF-CC750 | 30W | 750mA | 25-40V | 85 | 0.9 | |||||
HA-RFCH032BF-CC800 | 32W | 800mA | 25-40V | 85 | 0.9 | |||||
HA-RFCH034BF-CC850 | 34W | 850mA | 25-40V | 86 | 0.9 | |||||
HA-RFCH036BF-CC900 | 36W | 900mA | 25-40V | 86 | 0.9 | |||||
HA-RFCH038BF-CC950 | 38W | 950mA | 25-40V | 86 | 0.9 | |||||
HA-RFCH040BF-CC1000 | 40W | 1000mA | 25-40V | 86 | 0.9 | |||||

Item | |||||||
Voltage Range | AC 220-240V | ||||||
Limited Voltage | 264V AC | ||||||
Power Factor | >0.9 | ||||||
T.H.D | <10% | ||||||
Efficiency | 86% | ||||||
Output | Current Accuracy | ±3% | |||||
Power-on Time | <500ms | ||||||
Protection | Short Circuit | constant voltage mode, recover automatically after fault condition is removed | |||||
Over Loading | ≤120% constant voltage limiting, recover automatically after fault condition is removed | ||||||
Over Temperature | 100℃±10℃ Shut down o/p voltage, recovers automatically after temperature goes down | ||||||
Others | Ta | -20~+45℃ | |||||
Tc | 85℃ | ||||||
IP rating | IP20 | ||||||
Life span | 50000hours | ||||||
Warranty | 5years | ||||||
Notes | 1. All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25℃of ambient temperature. 2. Tolerance: includes set up tolerance, line regulation and load regulation . 3. The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | ||||||