Share on (1600469981239):
Power Systems | Power Type | Microwave power |
Power | 0~1250W | |
Frequency | 2.45GHz | |
Vacuum System | Two-stage rotary vane pump (oil pump) | 60m3/h(Optional dry pump) |
Vacuum line | All stainless steel pipes, and high-strength vacuum bellows | |
Material | Aluminum alloy (customized stainless steel cavity) | |
Thickness | 25mm | |
Tightness | Military grade welded seal | |
Inner Chamber size | 450×450×450mm(W×H×D) | |
Workspace | 6 magazine sections | |
ECR | Slotted Magazine and provides ECR enhanced treatment | |
Tray rotation | Magnetic fluid control tray rotation | |
Gas system | Flow range | 0~300SCCM |
Process gas circuit | Standard two-way CF4 gas optional | |
Control System | System control | PLC |
Interactive mode | 7 inch touch screen | |
Other specification | Machine size | 1300×2100×1200mm(W×H×D) |
Weight | 250KG | |
Color | Silver grey |
AC Power Specifications | Power supply: | AC380V,50/60Hz,5-wire,50A |
Factory exhaust | Flow | 2.0 m³/min |
Flow | 1~10 L/min | |
Pressure | 3~7 kg/cm² | |
Factory working gas requirements | Pipe diameter | 6×4 mm |
Material | PU tube | |
purity | 99.99% above | |
Flow | 1~10 L/min | |
Pressure | 3~7 kg/cm² | |
Pipe diameter | 8×5 mm | |
Factory compressed air requirements | Material | PU tube |
dew point | -40℃below | |
Particle>0.3μm | 10Pcs/ft³ |
Danger signs | High Voltage Hazard Sign |
Use environment | Temperature :15~30℃ Humidity :30~70% |
Other considerations | No flammable gas, corrosive gas, explosive or reactive dust Cylinders need to be fixed |
No. | Name | Description | Unit | Qty |
1 | Host | Dimension:1300×2100×1200mm(W×H×D) | Set | 1 |
2 | Vacuum chamber | Vacuum chamber Inner size 450×450×450mm(W×H×D) | Set | 1 |
3 | Excitation power | Microwave plasma | Set | 1 |
Frequency:2.45GHz Power 0~1250W | ||||
4 | PLC | Siemens, Germany,S7-200 | Pcs | 1 |
5 | Touch screen | MCGS, seven-inch screen | Pcs | 1 |
6 | Flowmeter | WAWICK | Pcs | 2 |
7 | Vacuum pump set | Leybold two-stage rotary vane pump (oil pump):60m3/h | Set | 1 |
8 | Vacuum gauge | INFICON | Pcs | 1 |
9 | Manual | Operation Manual of Vacuum Microwave Plasma Cleaner SPMV-100H | Set | 1 |
Item | Inspection contents | Life | Inspection frequency |
Oil pump | Filter element | Usage time 2000H | 15-day |
Pump oil | Usage time 2000H | 15-day |
New products from manufacturers at wholesale prices