Product Description
Programmable High And Low Temperature Humidity Test Chamber Thermal Shock Machine Testing Equipment For Metal Corrosion
What is a Two-Zone Thermal Shock Chamber ?
2-Zone Thermal Shock Chambers from ATMARS consist of two separately controlled hot and cold zones (one atop the other) with product being transferred vertically by a pneumatic basket for rapid product temperature changes. The conditioned air is pre-cooled or pre-heated beyond the setpoint, allowing quicker recovery of the desired condition after transfer.
The induced thermal stresses can reveal hidden manufacturing defects in electronic sub-assemblies and other components by the expansion and contraction of critical parts, ideal for testing to find product flaws before they reach your customers.
pecifications of ATS2-150L Series Temperature Test Chamber
*Performance is based on ambient temperature +25 ℃ or circulating water temperature +25 ℃, empty load.
Model
|
ATS2-
|
80A
|
80B
|
80C
|
Performance
|
Temperature range
|
-55℃ to +180℃
|
-70℃ to +180℃
|
-75℃ to +180℃
|
Thermal shock range
|
-40℃ to +150℃ Hot: +60℃ to +150℃ Cold: -40℃ to -10℃
|
-55℃ to +150℃ Hot: +60℃ to +150℃ Cold: -55℃ to -10℃
|
-65℃ to +150℃ Hot: +60℃ to +150℃ Cold: -65℃ to -10℃
|
Temperature fluctuation
|
≤±0.5℃
|
Temperature deviation
|
≤±2.0℃
|
Temperature uniformity
|
±2.0℃
|
Recovery time
|
≤5min.
|
Transfer time
|
≤10sec.
|
Temperature overshoot
|
≤±2.0℃
|
Hot zone
|
+60℃ to +180℃
|
Preheating time
|
+60℃ to +180℃ in 30min.
|
Cold zone
|
-55℃ to -10℃
|
-70℃ to -10℃
|
-75℃ to -10℃
|
Precooling time
|
+20℃ to -55℃ in 45min.
|
+20℃ to -70℃ in 45min.
|
+20℃ to -75℃ in 45min.
|
Test room
|
-40℃ to +150℃
|
-55℃ to +150℃
|
-65℃ to +150℃
|
Exposure time Test room recovery time
|
High temperature exposure for 30min.
|
Low temperature exposure for 30min.
|
within 5min.
|
Workspace volume
|
80L
|
Workspace dimensions (WxDxH)mm
|
500*400*400 |
Exterior dimensions (WxDxH)mm
|
1350*2070*2000 |
Material
|
Interior
|
Matte SUS #304 Stainless Steel Plates
|
Exterior
|
Powder Coated Carbon Steel Plates
|
Seal
|
Imported Silicone Seal
|
Insulation
|
Hard Polyurethane Foam Insulation and Glass Wool
|
System
|
Heating
|
Nichrome Wire Electric Heater
|
Refrigeration
|
German GEA Cascade Semi-Hermetic Compressors or Other Brands Air-cooled or Water-cooled Cooling Mode for Option Zero Ozone Depletion Potential (ODP) Refrigerant - R404A / R23
|
Allowable ambient conditions
|
Temperature: +5℃ to +35℃; Relative humidity: ≤85%RH (No condensation); Air pressure: 86kPa to 106kPa
|
Electrical supply
|
AC 380 (1±10%)V (50±0.5)Hz 3 Phase 4 Wire plus Earth Wire
|
Custom options available
|