Share on (1600519339086):
MODEL | 1012 | 1512 | 2012 | 3024 | 5024 | ||||
Input | |||||||||
Voltage(DC) | 12V/24V | 12V/24V | 12V/24V | 24V/48V | 24V/48V | ||||
Nominal Voltage | 220VAC/110VAC | ||||||||
Voltage Range | 154-265VAC/77-135VAC | ||||||||
Frequency | 50-60Hz Auto sensing | ||||||||
PV Input Voltage Range (MPPT/PWM Controller) | 12V:MPPT 15V-150VDC / PWM 15V-30VDC 24V:MPPT 30V-150VDC / PWM 30V-60VDC 48V:MPPT 60V-150VDC / PWM 60V-105VDC | ||||||||
Output | |||||||||
Rated Power | 800W | 1200W | 1600W | 2400W | 4000W | ||||
Voltage | 220VAC/110VAC(±10% ups mode) | ||||||||
Frequency | 50/60Hz | ||||||||
Waveform | Pure sine wave | ||||||||
Transfer Time(AC to DC) | <8ms | ||||||||
Transfer Time(DC to AC) | <8ms | ||||||||
Output Voltage Regulation | 10%rms | ||||||||
Bypass Mode | Yes | ||||||||
Saver Mode | Yes | ||||||||
Efficiency | >98% | ||||||||
Protection | |||||||||
Input Protection | Circuit Breaker | ||||||||
Output Protection | Circuit Breaker | ||||||||
Battery | |||||||||
Battery Type | AGM-Deep Cycle, GEL | ||||||||
Up to 500Ah | |||||||||
Charging Current | 20/10A | 30/15A | 35/18A | 30/15A | 40/20A | ||||
Low Level Disconnect(Selectable) | (10V or 10.5V)✖N N means the number of batteries in series | ||||||||
LCD Indicator Status | Input AC, Output AC | ||||||||
Battery DC, Output Load | |||||||||
Alarm, Fault | |||||||||
Battery Charge Level | |||||||||
Output Frequency | |||||||||
LED Indicator Status | AC Line In: Green | ||||||||
Inverter: Green | |||||||||
Charging: Yellow | |||||||||
Alarm: Red | |||||||||
Alarm | |||||||||
Low Battery Alarm | Audible alarm-1 beeping per second | ||||||||
Overload Alarm | Audible alarm-continuous beeping | ||||||||
Fault | Audible alarm-continuous beeping | ||||||||
Environment | |||||||||
Temperature | 0-40°C | ||||||||
Humidity | C0-95%, Non condensing | ||||||||
Accoustic Noise(db) | <45dB | ||||||||




















New products from manufacturers at wholesale prices