Fluke 717 series Pressure Calibrator   :


 






The Fluke 717 Pressure Calibrators delivers outstanding performance, durability and reliability. These calibrators are compact, lightweight, and easy to carry. With a push button interface similar to the multifunction Fluke 740 Series Documenting Process Calibrators, the 717s are easy to use. They are EMI tolerant, dust and splash resistant, and feature a removable battery door for quick battery changes.


These calibrators come in 9 models measuring pressure up to 5000 psi/345 bar and are compatible with Fluke 700Pxx differential, gauge and absolute pressure modules to increase functionality.


 


*****Features at a Glance:



  • Measure pressure, 0.05% of full scale with internal sensor up to 5000 PSI/345 bar sensor (5000G model)

  • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24V loop power

  • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules

  • 1/8 NPT female pressure fitting

  • Compatible with non-corrosive Gases and liquids

  • Select eleven different engineering units

  • Zero, min, max, and hold functions

  • Calibrate P/I instruments with simultaneous pressure and current measurement

  • Pressure switch test function captures set, reset and Deadband values of a pressure switch

  • Error% calculation of mA measurements for quick pass-fail decisions

  • Long lasting battery life

  • Holster features test lead storage

  • Compatible with Toolpack magnetic hanging system

  • New switch test


-------------------------------------------


 

















Measurement Accuracy
Pressure







































































































































































































































717 Series 
Measure Pressure (internal sensor)
Accuracy: 0.05% full scale
Functions: Zero, Min, Max, Hold, Damp
  Note Gasses / liquids (non-corrosive)
  
Fluke 717 1G 
Range: -1 to 1 PSI, (-68.9 mbar to 68.9 mbar, -83 to 6.89 kPa)
Resolution: 0.0001 PSI, 0.001 mbar, 0.0001 kPa
Over Pressure: 5 X Full Scale
  
Fluke 717 30G 
Range: -12 to 30 PSI, (-850 mbar to 2 bar, -83 to 206.84 kPa )
Resolution: 0.001 PSI, 0.1 mbar, 0.01 kPa
Over Pressure: 2 X full scale
  
Fluke 717 100G 
Range: -12 to 100 PSI, (-850 mbar to 7 bar, -83 to 689.48 kPa)
Resolution: 0.01 psi, 0.1 mbar, 0.01 kPa
Over Pressure: 2 X full scale
  
Fluke 717 300G 
Range: -12 to 300 PSI, (-850 mbar to 20 bar, -83 to 2068.42 kPa )
Resolution: 0.01 PSI, 1 mbar, 0.1 kPa
Over Pressure: 375 PSI, 25 bar
  
Fluke 717 500G 
Range: 0 to 500 PSI, (0 mbar to 34,7 bar, 0 to 3447.38 kPa )
Resolution: 0.01 PSI, 1 mbar, 0.1 kPa
Over Pressure: 2 X full scale
  
Fluke 717 1000G 
Range: 0 to 1000 PSI, (0 mbar to 69 bar, 0 to 6894.76 kPa )
Resolution: 0.1 PSI, 1 mbar, 0.1 kPa
Over Pressure: 2 X full scale
  
Fluke 717 1500G 
Range: 0 to 1500 PSI, (0 bar to 103.4 bar, 0 to 10342 kPa )
Resolution: 0.1 PSI, 0.01 mbar, 1 kPa
Over Pressure: 2 X full scale
  
Fluke 717 3000G 
Range: 0 to 3000 PSI, (0 bar to 207 bar, 0 to 20684.27 kPa)
Resolution: 0.1 PSI, 0.01 bar, 1 kPa
Over Pressure: 2 X full scale
  
Fluke 717 5000G 
Range: 0 to 5000 PSI, (0 bar to 345 bar, 0 to 34474 kPa)
Resolution: 0.1 PSI, 0.01 bar, 1 kPa
Over Pressure: 2 X full scale
  
Fluke 717 Series with Pressure Modules 
Measure Pressure (via pressure module connector using optional Pressure Modules)
Range: 29 pressure modules, 0-1 inH20 to 10,000 PSI, 2.5 mbar to 700 bar ranges. Over pressure per pressure module specs
Resolution: Per pressure module specs
Accuracy: per pressure module specs
Functions: Zero, Min, Max, Hold, Damp

Current















Range: 0 to 24 mA (-25% to 125%)
Resolution: 0.001 mA
Accuracy: 0.015% + 2 counts



 

















Specifications
Loop Power















Range: 24 V dc
Accuracy: +/- 10%
  Note: Drive; 20 mA into 1000 ohms for battery >6.8V; 700 W for battery 5.8 to 6.8 V

Display







  Clear 5 digit LCD



 

























Environmental Specifications
Operating Temperature







  -10 ºC to 55 ºC

Storage Temperature







  -40 ºC to 60 ºC

Humidity (Without Condensation)



















  95% (10 ºC to 30 ºC)
  75% (30 ºC to 40 ºC)
  45% (40 ºC to 50 ºC)
  35% (50 ºC to 55 ºC)

Operating Altitude







  3,000 M max



 













Safety Specifications
Safety







  CSA C22.2 No. 1010.1:1992



 





























Mechanical & General Specifications
Size







  201 mm L x 98 mm W x 52 mm (7.93in. L x 3.86in. W X 2.06in.)

Weight







  22 oz, approximately 600G with holster

Warranty







  3 years

Shock & Vibration











  Random, 2G, 5-500 Hz
  1m drop test

Battery type







  Single 9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline



 






 


 


 


-----------------------------------------------------------------