Under voltage alarm | Input voltage below than 10.5V±0.2V in to under voltage alarm | ||||||
Undervoltage protection | Input voltage below than 10V±0.2V,in to shutdown protection | ||||||
Overvoltage protection | Input voltage over than 16±0.2V,in to shutdown protection | ||||||




MODEL | RSC2000P-112 | RSC2000P-124 | RSC2000P-212 | RSC2020P-224 | |||||
Rated Power | 2000W | ||||||||
Maximum Output Power | 2200W for 180 Sec./2400W for 10 Sec./Surge power 4000W for 2 Sec. | ||||||||
AC Voltage | Factory setting set at 110V AC | Factory setting set at 230V AC | |||||||
100/110/115/120VAC(Optional) | 220/230/240VAC(Optional) | ||||||||
Wave Form | Ture Sine Wave(THD<4%)at rated input voltage | ||||||||
Standard Receptacles | Schuko/UK/Australia/Universal/USA/France/JP/Brazil | ||||||||
Battery Voltage | 12V | 24V | 12V | 24V | |||||
DC Current | 150A | 75A | 150A | 75A | |||||
Efficiency | 92% | 93% | 93% | 94% | |||||
Battery types | Recommend use Lithium &sealed lead acid battery | ||||||||
Charger current range | 4~20A | 2~10A | 4~20A | 2~10A | |||||
Max output voltage | 14.8VDC | 29.6VDC | 14.8VDC | 29.6VDC | |||||
Absorption voltage | 14.6VDC | 29.2VDC | 14.6VDC | 29.2VDC | |||||
Float voltage | 13.8VDC | 27.6VDC | 13.8VDC | 27.6VDC | |||||
BYPASS | Relay | 30A | |||||||
PROTECTIONS | Reverse polarity/battery low voltage alarm/shut down/over voltage/over load/over current/over temperature/short circuit/earth leakage | ||||||||