Share on (1600527832788):














MODEL | KS-2000-112 | KS-2000-124 | KS-2000-148 | KS-2000-212 | KS-2000-224 | KS-2000-248 | |||||||
RATED POWER | 2000W | ||||||||||||
MAXIMUM OUTPUT POWER | 2200W for 180 sec. / 2400W for 10 sec. / surge power 4000W for 2 sec | ||||||||||||
AC VOLTAGE | Factory Setting set at 110V AC | Factory Setting set at 110V AC | |||||||||||
100/110/115/120VAC (Option) | 220/230/240VAC Option | ||||||||||||
FREQUENCY | Factory Setting set at 60Hz (50/60Hz Option) | Factory Setting set at 50Hz (50/60Hz Option) | |||||||||||
WAVE FORM | Ture Sine Wave(THD<3%)at rated input voltage | ||||||||||||
AC REGULATION | 5% | ||||||||||||
STANDARD RECEPTACLES | Schuko/UK/Australia/Universal/USA/France/JP/Brazil | ||||||||||||
FRONT PANEL INDICATOR | Operation and Fault status | ||||||||||||
BAT. VOLTAGE | 12V | 24V | 48V | 12V | 24V | 48V | |||||||
VOLTAGE RANGE | 10.8 - 15.5VDC | 21.6-31VDC | 43.2 〜62VDC | 10.8 - 15.5VDC | 21.6-31VDC | 43.2 〜62VDC | |||||||
DC CURRENT | 200A | 100A | 50A | 200A | 100A | 50A | |||||||
FUSE | 35A*8 | 20A*8 | 10A*8 | 35A*8 | 20A*8 | 10A*8 | |||||||
NO LOAD CURRENT DRAW | 0.85A | 0.42A | 0.21A | 0.85A | 0.42A | 0.21A | |||||||
EFFICIENCY | 89% | 91% | 92% | 90% | 92% | 93% | |||||||
BATTERY TYPES | Recommend use Open & sealed lead acid battery | ||||||||||||
BAT.LOW ALARM | 10.8+/-0.2V | 21.6+/-0.4V | 43.2+/-0.8V | 10.8+/-0.2V | 21.6+/-0.4V | 43.2+/-0.8V | |||||||
BAT.LOW SHUTDOWN | 10.2+/-0.2V | 20.4+/-0.4V | 40.8+/-0.8V | 10.2+/-0.2V | 20.4+/-0.4V | 40.8+/-0.8V | |||||||
BAT.OVER SHUTDOWN | 15.5+/-0.2V | 31+/-0.4V | 62+/-0.8V | 15.5+/-0.2V | 31+/-0.4V | 62+/-0.8V | |||||||
REVERSE POLARITY | Built in fuse | ||||||||||||
OVER TEMPERATURE | 75°C | ||||||||||||
OUTPUT SHORT CIRCUIT | Protection type : Shut down o/p voltage, re-power on to recover | ||||||||||||
OVER LOAD | 120% Rated power / Protection type : Shut down o/p voltage, re-power on to recover within 10 times. | ||||||||||||
BYPASS | BUILT IN RELAY | 30A | |||||||||||
WORKING TEMP. | 0 〜+40°C @100% Load; 60 °C @ 50% Load | ||||||||||||
WORKING HUMIDITY | 20%-90% RH non-condensing | ||||||||||||
STORAGE TEMP | -30-+70 °C /-22~+158° F | ||||||||||||
STORAGE HUMIDITY | 10-95% RH non-condensing | ||||||||||||
CE | Compliance to EN61000-3-2,3 | ||||||||||||
LVD | Compliance to EN60950-1 | ||||||||||||
ROHS | Compliance to EN1122B:2001-1 | ||||||||||||
LOW BAT ALARM | Buzzer sound 2 times and Red light blink 2 times every 8 Sec | ||||||||||||
LOW BAT SHUT DOWN | Buzzer sound 3 times and Red light blink 3 times every 8 Sec | ||||||||||||
OVER BAT SHUT DOWN | Buzzer sound 4 times and Red light blink 4 times every 8 Sec | ||||||||||||
OVER TEMP | Buzzer sound 5 times and Red light blink 5 times every 8 Sec | ||||||||||||
OVER LOAD | Light Blink Constantly | ||||||||||||
COOLING | Load and Temp control the Fan | ||||||||||||
CONTROL WIRING | RJ11 | ||||||||||||
DIMENSION | 380*220*9 0mm (L*W*H) | ||||||||||||
PACKING | 7KG;2PCS/15KGS/CARTON | ||||||||||||
APPLICATION | Home and office appliances, Power Tools and Portable Equipment, Vehicle,Yacht and Solar System | ||||||||||||
NOTE | 1 .Volue test by input voltage at 13V,26V,48V. 2 .All parameters are measured at rated load, 2 5 °C of ambient temperature. 3.The specifications are subject to change w辻hout prior notice for further improvement of products | ||||||||||||



New products from manufacturers at wholesale prices