Output G Calculation Formula
G = 0.06 VnKρ (t/h)
In the formula: V---- volume of rotary valve (L) n---- speed (r/min) ρ---- bulk density of material (t/m³) K---The filling factor
is 0.6~0.8 for particles and 0.4~0.6 for powder For example:a 9L flour pneumatic conveying rotary valve output:
G=0.06*9*53*0.5*0.5=7.155(t/h)