Share on (1600533974061):
High Performance Gas Chromatography Instrument Machine Price
Product Introduction
GC6000 gas chromatography is equipped with FID6000 detector and ASL6000 automatic sampler; it can be equipped with FPD, ECD and other detectors, and it can be equipped with Wanyi self-produced air purification system.
Product Parameter
| High Performance Gas Chromatography Instrument Machine Price | |
| Product Name | Gas Chromatography |
| Detector | FID |
| Sampler | Autosampler or Six-way valve |
| Position | 120 |
| Laboratory environment | |
| Supply voltage | 220V±10% |
| Temperature | 18-28℃ |
| Humidity | 40-70% |
| Whole machine parameters | |
| Qualitative repeatability | ≤0.1% |
| Quantitative repeatability | ≤1.5% |
| Baseline noise | 0.01pA |
| Baseline drift | 0.1pA/30min |
| Sampler | |
| Linearity | 0.999 |
| Cross-contamination | 0.01% |
| Number of injection bits | 16 bits |
| Number of reagent bits | 3 bits |
| Column chamber | |
| Above room temperature | +4℃-450℃ |
| Programmed temperature rise rate | 40℃/min |
| Program temperature rise repeatability | <0.5% |
| Minimum adjustment amount | ≤0.01℃ |
| Temperature control accuracy | ±0.05℃ |
| Maximum run time | 999.9min |
| Detector (hydrogen flame (FID) detector) | |
| Maximum operating temperature | 450 ℃ |
| Minimum detection limit | 2.5pg / s |
| Linear range | ≥ 106 |
Product Performance
1.1 The whole machine realizes computer control;
1.2 Rich self-diagnosis and alarm functions;
1.3 Multi-step program temperature rises to meet the various needs of users. The door opening mechanism after the oven is controlled by a computer can realize rapid automatic program heating and rapid automatic cooling.
2.1 Very low noise, FID noise is better than the international leading level;
2.2 High sensitivity detector, low baseline drift;
2.3 Good reproducibility of peak area and retention time;
2.4 With high temperature control accuracy and good stability, the column thermostat provides a constant temperature environment for the effective separation and detection of various components.
3.1 Very low noise, FID noise is better than the international leading level;
3.2 High sensitivity detector, low baseline drift;
3.3 Good reproducibility of peak area and retention time;
3.4 With high temperature control accuracy and good stability, the column thermostat provides a constant temperature environment for the effective separation and detection of various components.
4.1 Optional multiple detectors (FID, FPD, ECD);
4.2 Any two detectors and two chromatographic columns can be installed at the same time; It can have three independent circuits, gas system and three signal output terminals at the same time;
4.3 Flexible syringe injection system, optional autosampler or six-port valve injection;
4.4 Automatic backflushing, automatic carrier gas switching, septum purge and one-time sampling automatic full analysis system;
4.5 The shunt outlet is designed with a special collection tube to protect the EPC and create a clean and safe laboratory environment;
4.6 Can reserve a channel for combined use with mass spectrometry (according to customer requirements);
4.7 It has a wide range of applications and can provide the best solution for many analysis fields.


New products from manufacturers at wholesale prices