Share on (1600537237102):

1.Input parameters | Parameters | Unit | Test description | Minimum | Typical | Maximum | ||||
Input Voltage | V(AC) | Normal | 85 | 220 | 265 | |||||
Input frequency | HZ | Normal | 43 | 50 | 65 | |||||
Power factor | PF | Normal | 0.51 | 0.55 | 0.56 | |||||
Input Inrush Current | A | Cold start under normal conditions | ||||||||
2.Output parameters | Parameters | Unit | Minimum | Typical | Maximum | |||||
Output current | MA | 109 | 110 | 114 | ||||||
Output voltage | V | 27 | XX | 90 | ||||||
Output ripple | MV | |||||||||
Constant current accuracy | % | 1% | 3% | 5% | ||||||
3.Overall performance 9series connection110MA Test condition | AC Input | Output | ||||||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency | |||||
170 | 3.66 | 28.2 | 111 | 0.54 | 0.86 | |||||
180 | 3.68 | 28.2 | 112 | 0.53 | 0.86 | |||||
190 | 3.73 | 28.2 | 112 | 0.53 | 0.85 | |||||
200 | 3.74 | 28.2 | 112 | 0.52 | 0.84 | |||||
210 | 3.79 | 28.3 | 113 | 0.52 | 0.84 | |||||
220 | 3.81 | 28.2 | 113 | 0.51 | 0.84 | |||||
230 | 3.83 | 28.3 | 113 | 0.51 | 0.83 | |||||
240 | 3.88 | 28.3 | 114 | 0.51 | 0.83 | |||||
12series connection 110MA Test condition | AC Input | Output | ||||||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency | |||||
170 | 4.74 | 37.7 | 111 | 0.55 | 0.88 | |||||
180 | 4.78 | 37.7 | 111 | 0.54 | 0.88 | |||||
190 | 4.78 | 37.7 | 112 | 0.54 | 0.88 | |||||
200 | 4.86 | 37.8 | 112 | 0.53 | 0.87 | |||||
210 | 4.89 | 37.8 | 113 | 0.53 | 0.87 | |||||
220 | 4.93 | 37.8 | 113 | 0.52 | 0.87 | |||||
230 | 4.95 | 37.8 | 113 | 0.52 | 0.86 | |||||
240 | 5.01 | 37.8 | 113 | 0.52 | 0.85 | |||||
16series connection 110MA Test condition | AC Input | Output | ||||||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency | |||||
170 | 6.16 | 50.3 | 110 | 0.55 | 0.90 | |||||
180 | 6.2 | 50.4 | 110 | 0.55 | 0.89 | |||||
190 | 6.24 | 50.4 | 111 | 0.55 | 0.90 | |||||
200 | 6.27 | 50.3 | 111 | 0.54 | 0.89 | |||||
210 | 6.34 | 50.4 | 112 | 0.54 | 0.89 | |||||
220 | 6.38 | 50.3 | 112 | 0.53 | 0.88 | |||||
230 | 6.44 | 50.4 | 112 | 0.53 | 0.88 | |||||
240 | 6.46 | 50.4 | 113 | 0.53 | 0.88 | |||||
20series connection 110MA Test condition | AC Input | Output | ||||||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency | |||||
170 | 7.55 | 62.9 | 110 | 0.56 | 0.92 | |||||
180 | 7.6 | 62.9 | 110 | 0.55 | 0.91 | |||||
190 | 7.62 | 62.8 | 110 | 0.55 | 0.91 | |||||
200 | 7.68 | 62.9 | 110 | 0.55 | 0.90 | |||||
210 | 7.73 | 62.9 | 111 | 0.55 | 0.90 | |||||
220 | 7.79 | 62.9 | 111 | 0.54 | 0.90 | |||||
230 | 7.82 | 62.9 | 112 | 0.54 | 0.90 | |||||
240 | 7.91 | 63 | 112 | 0.54 | 0.89 | |||||
24series connection 110MA Test condition | AC Input | Output | ||||||||
Input Voltage(V) | Power consumption(W) | Output voltage(V) | Output current(MA) | Power Factor | Efficiency | |||||
170 | 8.99 | 75.5 | 109 | 0.56 | 0.92 | |||||
180 | 8.97 | 75.4 | 109 | 0.56 | 0.92 | |||||
190 | 9.04 | 75.5 | 109 | 0.56 | 0.91 | |||||
200 | 9.05 | 75.4 | 110 | 0.55 | 0.92 | |||||
210 | 9.11 | 75.4 | 110 | 0.55 | 0.91 | |||||
220 | 9.15 | 75.4 | 110 | 0.55 | 0.91 | |||||
230 | 9.23 | 75.5 | 111 | 0.54 | 0.91 | |||||
240 | 9.27 | 75.5 | 111 | 0.54 | 0.90 | |||||
4. Using environment Parameters | Parameters | Unit | Test description | Minimum | Typical | Maximum |
Working ambient temperature | ℃ | Full load operation | -18 | +40 | +60 | |
Storage ambient temperature | ℃ | -25 | 25 | +75 |