Share on (1600559128816):





specification | Model H9 | H9-1KW | H9-1.5KW | H9-2KW | H9-3KW | H9-4KW | ||||
Rated power | 1000W | 1500W | 2000W | 3000W | 4000W | |||||
Standard cell voltage | 12VDC/24VDC | 12VDC/24VDC | 12/24/48VDC | 24/48VDC | 24/48VDC | |||||
Size | Unit Dimensions | 510*255*205mm | ||||||||
Package Dimension LxWxH | 560*305*255mm | |||||||||
Weight | NET WEIGHT | 12kg | 14kg | 16kg | 18kg | 21kg | ||||
Gross Weight | 15kg | 17kg | 19kg | 22kg | 25kg | |||||
specification | Model H9 | H9-5KW | H9-6KW | H9-8KW | H9-10KW | H9-12KW | ||||
Rated power | 5000W | 6000W | 8000W | 10000W | 12000W | |||||
Standard cell voltage | 48/96VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96VDC | |||||
Size | Unit Dimensions | 510*255*205mm | 650*260*230mm | |||||||
Size | Package Dimension | 560*305*255mm | 700*310*270mm | |||||||
Weight | NET WEIGHT | 24kg | 26kg | 43kg | 46kg | 49kg | ||||
Gross Weight | 28kg | 30kg | 48kg | 51kg | 54kg | |||||
Input | DC input voltgae range | 10.5-15VDC (Single battery voltage) | ||||||||
Utility input voltgae range | 170-275VAC(220V) 85-138VAC(110V) | |||||||||
Utility input frequency range | 45-65HZ | |||||||||
Output | Inverter output efficiency | ≥85% | ||||||||
Inverter output voltage | 220VAC±2% 110VAC±2% | |||||||||
Inverter output frequency | 50/60HZ±1% | |||||||||
inverter output waveform | sine wave | |||||||||
Utility output voltage range | constant voltage output 220VAC±10% 110VAC±10% | |||||||||
Utility output frequency range | 50Hz 60Hz automatic tracking | |||||||||
Output waveform distortion | ≤3% | |||||||||
charging current | optional | C0=0A,C1=5A,C2=10A,C3=15,C4=20A,C5=25A,C6=30A | ||||||||
protection | Battery Lack-voltage alarm | 10.5VDC (Single battery voltage) | ||||||||
Battery low-voltage protection | 10VDC (Single battery voltage) | |||||||||
Battery over-voltage protection | 16.7VDC (Single battery voltage) | |||||||||
Battery over-voltage alarm | 15VDC (Single battery voltage) | |||||||||
Overload protection | rated power≥110%,60Spower off;≥130%,10Spower off;≥150%,0.6Spower off。 | |||||||||
Temperature protection | ≥85℃ alarm,≥90℃shutdown the machine | |||||||||
Working mode | 1 | Normal Mode: Utility is preferred, Utility is charging | ||||||||
02 | Eco Mode:load power≤10% shutdown the machine,≥11%-100%turn on | |||||||||
03 | Solar inverter is preferred,Utility is not charging,charging:battery voltage≥13V switch to inverter mode;Inverter:battery voltage≤10.5V, switch to utility mode | |||||||||
other | conversion time | ≤4ms | ||||||||
Panel Display | LCD | |||||||||
heat-dissipating method | Smart Fan Control | |||||||||
≤42℃ Fan slow turning heat dissipation,≥45℃ Fan high turning heat dissipation | ||||||||||
Work environment | noise | ≤55dB | ||||||||
temperature | -10-- +40℃ | |||||||||
elative humidity | <95% | |||||||||



New products from manufacturers at wholesale prices