Product Description


The Fuse Cutout are connected with the incoming feeder of the distribution transformer or distribution lines. These are primary used to protect transformers or lines from short circuits and overloads and switching currents. The drop out fuse unit is composed of insulator supports and a fuse tube, static contacts is fixed on two sides of insulator support and moving contact is installed on two ends of fuse tube. The interior of the fuse tube is the extinguishing tube, the exterior is made of phenolic compound paper tube or epoxy glass.








Specification




Type
Rated Voltage
(kv)
Rated Current
(A)
Breaking Current
(A)
Impulse Voltage
(BIL)(KV)
Power-frequency withstand voltage(KV)
Creepage Distance
(mm)
Weight

(kgs)
Dimension
(cm)

YK1-11
11-15
100
8000
110
40
240
6.5

40*36*11.5
11-15
200
10000
110
40
240
6.5

YK1-15
15-27
100
8000
125
45
320
8.5

50*32*12.5
15-27
200
10000
125
45
320
8.5

YK1-24
24-27
100
8000
150
65
510
10

50*38*16
24-27
200
10000
150
65
510
10

YK1-33
33-36
100
8000
170
70
660
13

64*35*18
33-36
200
10000
170
70
660
13




Type
Rated Voltage
(kv)
Rated Current(A)
Breaking Current
(A)
Impulse Voltage
(BIL)(KV)
Power-frequency withstand voltage(KV)
Creepage Distance
(mm)
Weight

(kgs)
Dimension
(cm)

HYK1-15
11-15
100
8000
110
40
320
5

40*36*11.5
11-15
200
10000
110
40
320
5

HYK1-24
24-27
100
8000
150
65
540
6

50*38*16
24-27
200
10000
150
65
540
6

HYK1-33
33-36
100
8000
170
70
720
7

64*34*16
33-36
200
10000
170
70
720
7

YK3-15
11-15
300
8000
110
40
240
6.5

40*36*11
11-15
400
1000
110
40
240
6.5


Name

Parameter
Type
IFC-12
Rated Voltage(kv)
12
Rated Frequency(HZ)
50
Fuse-base rated current(A)
50 /100
Fuse-rated current(A)
6, 10, 15, 20, 25, 30, 40, 50, 65, 75, 80, 100
Rated breaking current(KA)
12.5
Mechanical stability(Times)
500
Insulation class
B



Insulating property

name

Power-frequency withstand voltage(KV)

Power-frequency withstand (wet)(KV)

Lightning impulse(KV)
To Ground
42
30
75
Fracture
48
36
85


Packing & Shipping




!!!!!!!!Contact me as below guide, We are glad to give you the best price!!!!!!!!


HOT Products




Company Profile




Certifications




Recommend Products




!!!!!!!!Contact me as below guide, We are glad to give you the best price!!!!!!!!




1600591768380