Model | Bante900 | |
pH | ||
Range | -2.000 to 20.000pH | |
Resolution | 0.001/ 0.01/ 0.1pH, selectable | |
Accuracy | ±0.002pH | |
Calibration Points | 1 to 5 points | |
pH Buffer Options | USA/ NIST/ DIN/ 2 custom buffers | |
ORP | ||
Range | -1999.9 to 1999.9 mV | |
Resolution | 0.1 / 1 mV, selectable | |
Accuracy | ±0.2mV | |
Calibration Points | 1 point | |
Measurement Modes | Relative / absolute mV | |
Ion Concentration | ||
Range | 0.00 to 19999 (deponding on the range of ISE) | |
Resolution | 0.001, 0.01, 0.1, 1 automatic | |
Accuracy | ±0.5% F.S. (monovalent), ±1% F.S. (divalent) | |
Calibration Points | 2 to 5 points | |
Calibration Solutions | 0.001/ 0.01/ 0.1/ 1/ 10/ 100/ 1000/10000 | |
Measurement Units | ppm, mg/L, mol/L, mmol/L | |
Conductivity | ||
Range | 0 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm | |
Resolution | 0.001, 0.01, 0.1, 1 automatic | |
Accuracy | ±0.5% F.S. | |
Calibration Points | 1 to 5 points | |
Calibration Solutions | 10µS, 84µS, 1413µS, 12.88mS, 111.8mS | |
Temperature Coefficient | 0.0 to 10.0%/°C | |
Reference Temperature | 20/25°C | |
Pure Water Compensation | Yes | |
Cell Constant | K=0.1 / 1 / 10 / Custom | |
TDS | ||
Range | 0 to 10.00, 100.0, 1000ppm, 10.00, 200.0ppt | |
Resolution | 0.01, 0.1, 1 automatic | |
Accuracy | ±1% F.S. | |
TDS Conversion Factor | 0.1 to 1.0 (default 0.5) | |
Salinity | ||
Range | 0.00 to 80.00ppt, 0.00 to 42.00psu | |
Resolution | 0.01 | |
Accuracy | ±1% F.S. | |
Resistivity | ||
Range | 0.00 to 20.00MΩ | |
Resolution | 0.01 | |
Accuracy | ±1% F.S. | |
Dissolved Oxygen | ||
Range | 0.00 to 20.00 mg/L / 0.0 to 200.0 % saturation | |
Resolution | 0.01 / 0.1, selectable | |
Accuracy | ±0.2 mg/L / ±2.0 % | |
Calibration Points | 1 or 2 points | |
Pressure Correction | 60.0 to 112.5kPa/450 to 850mmHg, manual | |
Salinity Correction | 0.0 to 50.0g/L, manual | |
Temperature | ||
Range | 0 to 105°C/32 to 221°F | |
Resolution | 0.1°C/°F | |
Accuracy | ±0.5°C/±0.9°F | |
Offset Calibration | 1 point | |
Calibration Range | Reading ±10°C/°F | |
Other Specifications | ||
Temperature Compensation | 0 to 100°C / 32 to 212°F, manual or automatic | |
Hold Function | Manual / Auto-read measurement endpoint | |
Stability Criteria | Low / High | |
Calibration Due Alarm | 1 to 31 days or off | |
Auto-Power Off | 10 / 20 / 30 minutes after last key pressed | |
Memory | Stores up to 500 data sets | |
Output | USB communication interface | |
Connector | BNC, 6-pin mini-DIN, 3.5 mm jack socket | |
Display | Custom LCD (125*100mm) | |
Power Supply | 5V DC power adapter | |
Environmental Conditions | 0 to 50°C / 32 to 122°F, relative humidity < 80% | |
Dimensions | 210*188*60mm | |
Weight | 1.5kg | |