Share on (1600619988976):










S-350 350W Switching Power Supply | ||||||||||||||
Project | Technical index | |||||||||||||
Output | DC voltage | 5V | 12V | 18V | 24V | 36V | 48V | |||||||
Rated current | 50A | 29A | 19.4A | 14.5A | 9.7A | 7.3A | ||||||||
Rated power | 250W | 350W | 350W | 350W | 350W | 350.4W | ||||||||
Ripple and noise ① | <150mV | <150mV | <150mV | <150mV | <240mV | <240mV | ||||||||
Voltage accuracy | ±2% | ±1% | ||||||||||||
Output voltage regulation range | ±10% | |||||||||||||
Load adjustment rate | <±1.5% | <±1.2% | <±1.2% | <±1% | <±0.5% | <±0.5% | ||||||||
Linear adjustment rate | <±1% | |||||||||||||
Input | Voltage range | 90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC | ||||||||||||
Efficiency (typical) ② | >74% | >82% | >82% | >84% | >86% | >86% | ||||||||
Working current | <5.2 A 115VAC <2.8A 230VAC | |||||||||||||
Impulse current | 110VAC 25A, 220VAC: 50A | |||||||||||||
Start, rise, hold time | 200ms、50ms、20ms :230VAC | |||||||||||||
Protect | overload protection | 105% - 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again | ||||||||||||
Overvoltage protection | Close output when ≥ 115% - 145% | |||||||||||||
Undervoltage protection | Close output when ≤ 10% - 45% | |||||||||||||
Short circuit protection | Close output | |||||||||||||
Over temperature protection | Rth3: ≥ 65 ℃ fan start, ≥ 55 ℃ fan close, ≥ 80 ℃ close output (5v-15v) rth3: ≥ 70 ℃ fan start, ≥ 60 ℃ fan close, ≥ 85 ℃ close output (18v-48v) | |||||||||||||
Environmental Science | Working temperature and humidity | -10℃~+50℃;20%~90RH | ||||||||||||
Storage temperature and humidity | -20℃~+85℃;10%~95RH | |||||||||||||
Safety regulations | Withstand voltage | Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute | ||||||||||||
Leakage current | Input output < 6mA at 1.5kVac | |||||||||||||
Leakage current | < 1.5mA at input-output 220VAC | |||||||||||||
Isolation resistance | Input output, input shell, output shell: 500VDC / 100M Ω | |||||||||||||
Other | size | 215*115*50mm | ||||||||||||
Net weight / gross weight | 874.1/936.3g | |||||||||||||
Remarks | ① Ripple and noise measurement method: use a 12 "twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal, and measure at 20MHz bandwidth. ② The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature of 25 ℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under rated load from low voltage to high voltage test load regulation test method: from 0% - 100% rated load. The start-up time is measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ℃ / 1000m | |||||||||||||





New products from manufacturers at wholesale prices