Power supply units 5V 12V 24V 36V 48V 15W 25W 35W 50W 100W 150W 200W 350W smps power supply for CCTV Camera and LED Light

Share on (1600619988976):


Price:

Quantity:


Product Overview

Description



Product Description


















Specification


S-350 350W Switching Power Supply
Project
Technical index








Output
DC voltage
5V
12V
18V
24V
36V
48V
Rated current
50A
29A
19.4A
14.5A
9.7A
7.3A
Rated power
250W
350W
350W
350W
350W
350.4W
Ripple and noise ①
<150mV
<150mV
<150mV
<150mV
<240mV
<240mV
Voltage accuracy
±2%
±1%
Output voltage regulation range
±10%
Load adjustment rate
<±1.5%
<±1.2%
<±1.2%
<±1%
<±0.5%
<±0.5%
Linear adjustment rate
<±1%




Input
Voltage range
90-132VAC/180-264VAC 47Hz~63Hz;254VDC~370VDC
Efficiency (typical) ②
>74%
>82%
>82%
>84%
>86%
>86%
Working current
<5.2 A 115VAC <2.8A 230VAC
Impulse current
110VAC 25A, 220VAC: 50A
Start, rise, hold time
200ms、50ms、20ms :230VAC





Protect
overload protection
105% - 135% type: constant current output + VO reduced to undervoltage point cut off output reset: power on again
Overvoltage protection
Close output when ≥ 115% - 145%
Undervoltage protection
Close output when ≤ 10% - 45%
Short circuit protection
Close output
Over temperature protection
Rth3: ≥ 65 ℃ fan start, ≥ 55 ℃ fan close, ≥ 80 ℃ close output (5v-15v) rth3: ≥ 70 ℃ fan start, ≥ 60 ℃ fan close, ≥ 85 ℃ close
output (18v-48v)


Environmental Science
Working temperature and humidity
-10℃~+50℃;20%~90RH
Storage temperature and humidity
-20℃~+85℃;10%~95RH



Safety regulations
Withstand voltage
Input output: 1.5kVac input shell: 1.5kVac output shell: 0.5kvac for 1 minute
Leakage current
Input output < 6mA at 1.5kVac
Leakage current
< 1.5mA at input-output 220VAC
Isolation resistance
Input output, input shell, output shell: 500VDC / 100M Ω

Other
size
215*115*50mm
Net weight / gross weight
874.1/936.3g





Remarks
① Ripple and noise measurement method: use a 12 "twisted pair, and connect 0.1uF and 47uF capacitors in parallel at the terminal,
and measure at 20MHz bandwidth. ② The efficiency is tested at an input voltage of 230VAC, rated load, and an ambient temperature
of 25 ℃. Accuracy: including setting error, linear adjustment rate and load adjustment rate. Linear regulation test method: under
rated load from low voltage to high voltage test load regulation test method: from 0% - 100% rated load. The start-up time is
measured under the cold start state. The quick and frequent switch on and off may increase the start-up time. When the operating
altitude is higher than 2000m, the operating environment temperature needs to be reduced by 5 ℃ / 1000m


Company Profile








Our Team




Shipping&Delivery






FAQ


Q1:How many Voltage you can supply?
A: 12v , 24v , 48v ,50v , 60v , 110v(Depend on items).

Q2:Can I have a sample order?
A: Yes, we welcome sample order to test and check quality.Mixed samples are acceptable.

Q3:Do you have any MOQ limited for the order?
A: Low MOQ, 1pc for sample checking is available.

Q4:How do you ship the goods and how long does it take to arrive?
A: We usually ship by DHL, UPS, FedEx or EMS. It usually takes 3-5 days to
arrive. Airline and sea shipping also optional.

Q5:Do you offer guarantee for the products?
A: Yes, we offer warranty to our products.

Q6: How to deal with the faulty?
A: Firstly, our products are produced in strict quality control system and the defective rate will be less. Secondly, during the guarantee period,we will send new product with new order for small quantity. For defective batch products, we will repair them and resend them to you or we can discuss the solution including re-call according to real situation.


0.0913 s.