Datasheet | MAX 50KTL3 LV | MAX 60KTL3 LV | MAX 70KTL3 LV | MAX 80KTL3 LV | MID 40KTL3-X | MOD 8000TL3-X | MOD 9000TL3-X | |||||||
Max. recommended PV power ( tor module STC) | 75000W | 90000W | 105000W | 120000W | 60000W | 12000W | 13500W | |||||||
Start voltage | 250V | |||||||||||||
Nominal voltage | 585V | 585V | 600V | 600V | ||||||||||
No. of MPP trackers | 6 | 6 | 7 | 7 | ||||||||||
Max. input current per MPP tracker | 26A | |||||||||||||
Max. short-circuit current per MPP tracker | 32A | |||||||||||||
Output data (AC) | ||||||||||||||
AC nominal power | 50000W | 60000W | 70000W | 80000W | 40000W | 8000W | 9000W | |||||||
Max. AC apparent power | 55500VA | 66600VA | 77700VA | 88800VA | ||||||||||
Nominal AC voltage(range*) | 220V/380V, 230V/400V (340-440V) | |||||||||||||
AC grid frequency(range*) | 50/60 Hz (45-55Hz/55-65 Hz) | |||||||||||||
Max. output current | 80.5A | 96.6A | 112.7A | 128.8A | 66.6A | 13.3A | 15.0A | |||||||
AC grid connection type | 3W+N+PE | |||||||||||||
Efficiency | ||||||||||||||
MAX. efficiency | 98.8% | 98.8% | 99.0% | 99.0% | 98.80% | 98.60% | 98.60% | |||||||
European efficiency | 98.40% | 98.40% | 98.50% | 98.50% | 98.50% | 8.10% | 98.10% |