Instructions:1. Adjust the height of the whole machine cap wheel to fit the height of the bottle cap, and then adjust the height of the top cap. Pull the optical shaft of the top cap cylinder to the lowest level, and the POM of the top cap will be about 5mm lower than that of the bottle cap when it is released.
2. adjust the left and right sliders, so that the wheel and the bottle cap consistent contact, adjust the width and then lock the adjusting nut.
3.adjust the positioning of the bottle, so that the bottle cap is located in the center of the four wheels.
4. connect the trachea, power supply, gas, power.Push down the power switch, turn
the governor open, the three-gear switch to the manual, and then press the foot switch to operate the machine.
5. The left side of the double time relay is the interval time for adjusting the operation of the machine. Adjust the time according to the + and - signs, and adjust the capping time according to the right side, the operation mode is the same as the left.In general, the interval is only used in automatic mode, manual mode is not required.