Share on:
Data Sheet | HY-1200-Plus | |||||
Input Data(DC) | ||||||
Commonly Used Module Pairings | 4×300W~450W | |||||
Maximum Input DC Voltage | 60V | |||||
Power Point Tracking Voltage Range | 27~55v | |||||
Operating Range | 16~60V | |||||
Startup Voltage | 20V | |||||
Overvoltage Class DC Port | II | |||||
DC Port Backfeed Current | 0 A | |||||
PV Array Configuration | 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 25A per branch circuit | |||||
Max.Input Current | 4×20A | |||||
Output Data(AC) | ||||||
Peak Output Power | 1320W | |||||
Maximum Continuous Output Power | 1200W | |||||
Nominal (L-L) Voltage/Range | 240/211~264V | 208/183~229V | 230/Configurable | |||
Maximum Continuous Output Current | 5.00A | 5.77A | 5.21A | |||
Nominal Frequencyy/Range | 60Hz/59.3~60.5Hz | 50Hz/Configurable | ||||
Extended Frequency/Range | 45~55Hz / 55~65Hz | |||||
AC Short Circuit Fault Current Over 3 Cycles | 11Arms | |||||
Maximum Units Per 20 A (L-L) Branch Circuit | 3 | 3 | 3 | |||
Overvoltage Class AC Port | III | |||||
Power Factor(Adjustable) | >0.99 Default, 0.8 Leading... 0.8 Lagging... | |||||
Level of Harmonics Distortion | <3% | |||||
Efficiency | ||||||
CEC Weighted Efficiency | 95% | |||||
Peak Inverter Efficiency | 96.50% | |||||
Static MPPT Efficiency | 99% | |||||
Night Time Power Consumption | <50mW | |||||
Mechanical Data | ||||||
Ambient Temperature Range | -40ºC~+65ºC | |||||
Relative Humidity Range | 4% to 100% (condensing) | |||||
Dimensions(W*H*D) | 300×233×38 mm (Without mounting bracket and cable) | |||||
Weight | 5.33kg | |||||
Cooling | Natural Convection-No Fans | |||||
Approved for Wet Locations | Yes | |||||
Pollution Degree | PD3 | |||||
Enclosure Environmental Rating | IP67 | |||||
Environmental Category / UV Exposure Rating | NEMA Type 6 / outdoor | |||||
AC Cable Length(Integrated with AC Connectors) | 3m+ | |||||
Features | ||||||
Communication | PLC(Extra Data Logger) / Wi-Fi(Data Logger Built-in) | |||||
Monitoring | Support remote web page monitoring and local MDL monitoring | |||||
Disconnecting Means | The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. | |||||
Compliance | UL1741, INMETRO,VDE4105, VDE0126, IEC62109, EN50549, CE & INMETRO etc. | |||||
Warranty | 25 years |