Growatt MIC 750-3300TL-X | ||||||||||||||
Datasheet | 750TL-X | 1000TL-X | 1500TL-X | 2000TL-X | 2500TL-X | 3000TL-X | 3300TL-X | |||||||
Input Data | ||||||||||||||
Max. recommended PV power (for module STC) | 1050W | 1400W | 2100W | 2800W | 3500W | 4200W | 4290W | |||||||
Max. DC voltage | 500V | 500V | 500V | 500V | 550V | 550V | 550V | |||||||
Start voltage | 50V | 50V | 50V | 50V | 80V | 80V | 80V | |||||||
MPPT voltage range | 50V-500V | 50V-500V | 50V-500V | 50V-500V | 65V-550V | 65V-550V | 65V-550V | |||||||
Nominal voltage | 120V | 180V | 250V | 360V | 360V | 360V | 360V | |||||||
No. of MPP trackers | 1 | |||||||||||||
No. of PV strings per MPP tracker | 1 | |||||||||||||
Max. input current per MPP tracker | 13A | |||||||||||||
Max. short-circuit current per MPP tracker | 16A | |||||||||||||
Output (AC) | ||||||||||||||
AC nominal power | 750W | 1000W | 1500W | 2000W | 2500W | 3000W | 3300W | |||||||
Max. AC apparent power | 750VA | 1000VA | 1500VA | 2000VA | 2500VA | 3000VA | 3300VA | |||||||
Nominal AC voltage(range*) | 230V (180-280V) | |||||||||||||
AC grid frequency(range*) | 50/60 Hz (45-55Hz/55-65 Hz) | |||||||||||||
Max. output current | 3.6A | 4.8A | 7.1A | 9.5A | 11.9A | 14.3A | 14.3A | |||||||
Adjustable power factor | 0.8leading…0.8lagging | |||||||||||||
THDi | <3% | |||||||||||||
AC grid connection type | Single phase | |||||||||||||
Efficiency | ||||||||||||||
Max. efficiency | 97.4% | 97.4% | 97.4% | 97.4% | 97.6% | 97.6% | 97.6% | |||||||
Euro weighted efficiency | 96.5% | 96.5% | 97.0% | 97.0% | 97.0% | 97.1% | 97.1% | |||||||
MPPT efficiency | 99.9% | |||||||||||||



* The installation location must be suitable for the inverter's weight and dimensionsfor a long period time. | ||||||||
* Select the installation location so that the status display can be easily viewed. | ||||||||
* Do not install the inverter on structures constructed of inflammable or thermolabilematerials. | ||||||||
* Never install the inverter in environment of little or no air flow, nor dustenvironment.That may derate the efficiency of the cooling fan of the inverter. | ||||||||
* The lngress Protection rate is IP65 which means the inverter can be installedoutdoors and indoors. | ||||||||
* The humidity of the installation location should be 0~100% without condensation.The installation location must be freely and safely to get at all times. | ||||||||
* Vertically installation and make sure the connection of inverter must be downwards.Never install horizontal and avoids forward and sideways tilt. | ||||||||