Share on (1600760123347):
Cable Construction | ||
Extra-fine wires strands of bare copper, acc. to IEC 60228, Class 5 | ||
Modified PE compound | ||
Core identification: colored in acc. to VDE 0293-308 | ||
Four conductors stranded together in one layer | ||
Double screening with aluminium-coated plastic foil (metal-side outwards) and braiding of tinned copper wires, braid coverage 80% (nominal value). | ||
Sheath made of modified PVC, transparent or black (similar to RAL 9005) | ||
Technical Characteristics | ||||||||
Test voltage | * Core/Core: 4 kV * Core/Screen: 4 kV | |||||||
Minimum bending radius | * Occasional flexing: 15 x outer diameter * Fixed installation: 4 x outer diameter | |||||||
Nominal voltage | *U0/U: 600/1000 V | |||||||
Temperature range | * Flexing: -5°C to +70°C * 3+3 core version: -15°C to +70°C * Fixed installation: -40°C to +70°C | |||||||
Number of cores and mm² per conductor | Outer diameter [mm] | Copper index (kg/km) | Weight (kg/km) |
4 G 1.5 | 11.4 | 95 | 230 |
4 G 2.5 | 12.4 | 150 | 300 |
4 G 4.0 | 15.6 | 235 | 485 |
4 G 6.0 | 17 | 320 | 630 |
4 G 10.0 | 19.6 | 533 | 860 |
4 G 16.0 | 22.1 | 789 | 1290 |
4 G 25.0 | 26.3 | 1236 | 1860 |
SY Steel Wire Shielding Cable | ||
The cable is designed for connecting between frequency converter and motor, and applied in paper industry, chemical industry, heavy industry. Double shielding design also improves EMC noise situation of the whole drive system. In addition, it is can be used in dry, humid or wet conditions, indoor or outdoor environment. What’s more, FI SERVO 2YSLCYK-JB (3+3 structure) has a concentric conductor array design avoiding all cable-relevant parts from high frequency discharge currents. | ||