3 phase 25 kva generator price in dubai 27 kva diesel generator price with remote control for base station

Share on (1600795485159):


Price:$5,400.00 - $7,600.00

Quantity:


Product Overview

Description



AGG Glance






* Base load application (No power on site, generator is only source of power)
* Automatic mains failure (AMF) application
* Automatic Mains Failure (AMF) with no break return application
* Full power control system (Multiple sets synchronizing with each other, or at the same time with the mains utility supply, etc.)


Features & Tech Info


Smart Operation & Control, Robust Design & Manufacturing


Main Components
Brand
Model
Note: 
1. Engine we work with: Cummins, Perkins, MTU, Volvo, YuChai, SDEC, etc; 
2. Alternator we work with: Leroy Somer, Marathon, Stamford, AGG; 
3. Controller we work with: ComAp, Smartgen, Deepsea, Deif.
Engine
Cummins
4B3.9-G2
Alternator
Leroy Somer
TAL A40 G
Controller
ComAp
MRS16


3 phase 25 kva generator price in dubai 27 kva diesel generator price with remote control for base station


Main Technical Data (Genset Model: AGC250P)


Voltage V
380
400
415
PRP kVA / kW
25 / 20
25 / 20
25 / 20
ESP kVA / kW
28 / 22
28 / 22
28 / 22
AMPS
38.0
36.1
34.8
Hz
50
50
50
RPM
1500
1500
1500
Phase
3
3
3
PF
0.8
0.8
0.8
Open Type
Dimensions: 1905x730x1415 (LxWxH) (mm)
Dry Weight:  700 (kg)
Sound Attenuated Type
Dimensions: 2500x1020x1671 (LxWxH) (mm)
Dry Weight: 1201 (kg)


Note:
1. For 50Hz, available voltage grade: 380V~440V; optional 200V~240V;
2. For 60Hz, available voltage grade: 380V~480V; optional 208V~240V;


Genset Performance Index


Parameter
Unit
Performance Index
Note: 
Data in the left table is for reference only. Any questions, please contact us.
Dropping of frequency
%
≤1
Steady state frequency band
%
≤0.5
Regulated declining range of relative frequency
%
≤3.5
Regulated rising range of relative frequency
%
≤+2.5
Transient frequency deviation
100% anticlimactic power
%
≤+10
Shock power
%
≤-7
Frequency recovery time
s
≤2
Relative frequency tolerance band
%
2
Mesomeric state voltage deviation
%
≤±0.5
Degree of unbalancedness of voltage
%
0.5
Transient voltage deviation
100% anticlimactic power
%
≤±20
Shock power
%
≤-15
Voltage recovery time
s
≤2


Supply Scope


Standard Supply Scope:
① Diesel engine
② Synchronous AC alternator
③ Main circuit breaker
④ Heavy duty fabricated steel base frame
⑤ Water cooling radiator
⑥ Auto controller ComAp MRS16
⑦ Maintenance-free battery
⑧ SUS bellows expansion joint & flue silencer
⑨ Soundproof canopy (for silent type only)


* Remote radiator;
* Residential silencer;
* Fuel-water separator;
* Heavy duty air cleaner;
* Oil drain extension & shut-off valve;
* Jacket water & oil preheater;
* Anti-condensation heater;
* Bearing & stator temperature sensor;
* AMF, Paralleling, or Grid-connection, control;
* ATS cabinet, Independent or parallel output cabinet;
* Electrical-actuated, or 4-pole main, circuit breaker;
* Sub base or daily fuel tank;
* Auto fuel adding system;
* Others.


9 kVA ~ 4000 kVA Open Type
Diesel Generator Set

7 kW ~ 3200 kW Silent & ISO Containerized Type
Diesel Generator Set



AGG Soundproof Silent Generator set:
① Fresh Air inlet
② Emergency stop button
③ Steel base frame
④ Control cabinet
AGG Soundproof Silent Generator set:
⑤ Power cable outlet
⑥ Forklift slot
⑦ Drain outlet
⑧ Maintenance door
⑨ Drag hole


Why Choose Us




Bespoke design & supply service to suit customers’ unique requirements:
* Factory integrated & tested control & switch gear solution or stand-alone controls
* Factory standard sequence of operation for generator sets paralleling
* Redundancy features (Master PLC, ring/redundant right control networks, hardwired backup, etc.)
* Control paralleling tie breakers










Certificates & Partners




FAQ


Q: What is the power range of your generator sets?
A: We can provide 1 KVA to 4000 kVA, with a voltage range of 110V~15000V and frequencies of 50Hz and 60Hz.

Q: What is the difference between prime power and standby power?
A: Prime power is applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Standby power is applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings.
Q: What is the difference between kW and kVA?
A: Generators are sized in both kW and kVA; where the kW is the real and actual power available and the kVA is the maximum apparent power that the generator is designed to handle.
Q: How much fuel does a diesel generator use and how is it stored?
A: Different engines have different efficiencies but as a very rough rule of thumb a modern engine uses around 210 litres per hour per 1000kVA. Each generator (up to 800kVA) has an internal fuel tank with various sizes. If you need additional bulk storage tanks, please feel free to consult.
Q: What is the supply scope of your generator set?
A: For our open type generator set, the supply scope is engine, alternator, radiator, island controller, circuit breaker, starting battery, SUS bellows expansion joint, flue silencer, etc.


Packing & Shipping




>> Ready-in-stock models can be delivered soon after payment is made; for customized or not ready models, lead time is normally within one month for one set.
>> Incoterms accepted by us are EXW, FCA, FAS, FOB, CFR, and CIF. For other terms, please feel free to consult.
>> For shipping, we normally deliver ordered gensets from port of Shanghai either by LCL or FCL.
>> Standard way of packaging is to wrap up the generator set with foam, plastic wrap or bubble film, such way is cost-effective, convenient, and efficient.
>> To provide better protection, we can also provide fumigation free plywood case or iron packing. Other packing methods are upon request.


0.1914 s.